Auto-cut 300 xt – Tweco 300 XT Auto-Cut 480V User Manual
Page 58

AUTO-CUT 300 XT
4-10
OPERATION
Manual 0-5300
Code
Message
Remedy / Comments
267
Inverter 2A No Input
Power
Inverter section may have no input power. Contactor W1 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
268
Inverter 2B No Input
Power
Inverter section may have no input power. Contactor W2 not closed; Defective contactor or
CB4 tripped; Inverter section input not connected; Defective Inverter.
269
Inverter 3A No Input
Power
Inverter section may have no input power. Contactor W2 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
270
Inverter 3B No Input
Power
Inverter section may have no input power. Contactor W2 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
271
Inverter ID reading
fault
CCM found ID values inconsistant during reading. CCM to an Inverter section ribbon damaged
or disconnected; Inproper ribbon cable routing.
CCM Status Code
Group 3 -- Gas Controller Status & Protocol
Code
Message
Remedy / Comments
301
Not used
Reserved for other models.
302
Reserved
No information available; Contact customer service
303
Gas Supply Pressure
out of range.
Autocut is in SET mode or Plasma gas pressure is too low; Defective gas pressure sensor
(PS1).
304
Gas Control Purging
Normal following power up or returning from Plasma Disable.
305
Not used
Reserved for other models.
306
Not used
Reserved for other future use.
307
Not used
Reserved for other models.
308
Gas Control Type
Mismatch
Wrong CCM, must be Auto-cut type.
309
Not used
Reserved for other models.
310
Not used
Reserved for other models.
311
Not used
Reserved for other models.
312
Not used
Reserved for other models.
313
Not used
Reserved for other models.