Cutskill 35a, 04 air supply connections – Tweco 35A CutSkill User Manual
Page 16

cutskill 35A
INSTALLATION
3-2
Manual 0-5104
Power Cord
This power supply includes an input power cord for single phase 220/240 VAC, 15 Amp power. Attach an ap-
proved plug rated for 230V single phase at 15A. Brown wire is hot/live, blue wire is neutral and green/yellow is
ground.
Gas Pressure Regulator/
Filter Assembly
Gas Pressure Gauge
Art # A-09408
Input Power
Cable
Figure 3-1 220/240V AC Power Source
When the power source input voltage is over or under the safe operating range, the alarm light will turn on, at the
same time the current output will be cut off.
If the power supply voltage continually goes beyond the safe work voltage range it will shorten the power source
life-span.
3.04 Air Supply Connections
A. Connecting Air Supply to Unit 
The	connection	is	the	same	for	compressed	air	or	industrial	compressed	air	in	gas	cylinders.	
1.	 Connect	the	gas	line	to	the	compressed	air	input	inlet	port	at	the	appropriate	pressure.		The	illustration	shows	
typical fittings as an example.
NOTE
For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions.
Do Not use Teflon tape as a thread sealer, as small particles of the tape may break off and block the
small gas passages in the torch.