beautypg.com

Cutmaster a80 – Tweco A80 CutMaster User Manual

Page 17

background image

CUTMASTER A80

Manual 0-4985

INTRODUCTION

2-3

2.05 Input Wiring Specifications

CutMaster A80 Power Supply Input Cable Wiring Requirements

Input voltage

Freq

Power Input

Suggested Sizes

Volts

Hz

kVA

I max

I

1

eff

Fuse (amps)

Flexible Cord

(Min. AWG)

Flexible Cord

(Min. mm

2

)

1 Phase

208

60

20.6

99

76

100

4 Type W

25 Type W

230

60

21.9

95

74

100

4 Type W

25 Type W

460

60

27.6

60

46

60

6

15

3 Phase

208

60

17.7

49

38

60

6

15

230

60

17.9

45

36

60

6

15

380

50

18.4

28

22

32

10

6

400

50

18.7

27

22

32

10

6

460

60

23.1

29

22

30

10

6

600

60

22.8

22

17

25

12

4

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electric Code

NOTE

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations

refer to local or national codes.

I1max is taken at TDC rated minimum duty cycle.
I1eff is taken at TDC 100% rated duty cycle.