Cutmaster 52 – Tweco 52 CutMaster User Manual
Page 57
CUTMASTER 52
Manual 0-4961
SERVICE
5-7
6. Disconnect the input line from the filter element
assembly.
7. Remove the filter element assembly through the
rear opening.
NOTE
If replacing or cleaning just the filter element
refer to the following illustration for disas-
sembly.
Art # A-07990
Filter Element
8. Install the new or cleaned assembly by reversing these
procedures.
9. Turn ON the air supply and check for leaks before
reinstalling the cover.
Optional Single-Stage Filter Element Replacement
These instructions apply to power supplies where the
optional Single-Stage Filter has been installed.
The Power Supply shuts down automatically when
the Filter Element becomes completely saturated. The
Filter Element can be removed from its housing, dried,
and reused. Allow 24 hours for Element to dry. Refer
to Section 6, Parts List, for replacement filter element
catalog number.
1. Remove power from power supply.
2. Shut OFF air supply and bleed down system
before disassembling Filter to change Filter Ele-
ment.
3. Disconnect gas supply hose.
4. Turn the Filter Housing Cover counter-clockwise
and remove it. The Filter Element is located
inside the Housing.
Art # A-02476
Filter
Element
(Cat. No. 9-7741)
Housing
Cover
Barbed
Fitting
Spring
Assembled Filter
O-ring
(Cat. No. 9-7743)
Optional Single-Stage Filter Element Replacement
5. Remove the Filter Element from the Housing and
set Element aside to dry.
6. Wipe inside of housing clean, then insert the
replacement Filter Element open side first.
7. Replace Housing on Cover.
8. Reattach gas supply.
NOTE
If unit leaks between housing and cover,
inspect the O-ring for cuts or other damage.
Optional Two-Stage Filter Element Replacement
The Two-Stage Air Filter has two Filter Elements. When
the Filter Elements become dirty the Power Supply will
continue to operate but cut quality may become unac-
ceptable. Refer to Section 6, Parts List, for replacement
filter element catalog number.
1. Shut OFF primary input power.
2. Shut OFF air supply and bleed down system.
WARNING
Always turn OFF the air supply and bleed
the system before disassembling the Filter
Assembly as injury could result.
3. Loosen the two bolts on the top of the Filter As-
sembly enough to allow the Filter Elements to
move freely.
4. Note the location and orientation of the old Filter
Elements.
5. Slide out the old Filter Elements.