beautypg.com

03 primary input power connections, Primary input power connections -2, Cutmaster 39 – Tweco 39 CutMaster User Manual

Page 24

background image

cutmaster 39

INSTALLATION

3-2

Manual 0-4975

3.03 Primary Input Power Connections

CAUTION

Check your power source for correct voltage before plugging in or connecting the unit. The primary power source,
fuse, and any extension cords used must conform to local electrical code and the recommended circuit protection
and wiring requirements as specified in Section 2.

Power Cords Included With Power Supply

Attached to the power supply is an input power cord with a twist-lock plug NEMA L6-20P for use on a 240V/20A

system.

Also included are two addapter cords. One has a 120V/15A NEMA 5-15P plug for use with current settings up to

20 Amps. (Higher settings may result in tripping of 15 Amp curcuit breaker).

The other adapter cord is equiped with a 240V/20A NEMA 6-50P plug. Each of these adapter cords attaches to the

power supply input cord via the twist-lock connection.

Input Power Cord With NEMA L6-20P

Adapter for 120V/15A With NEMA 5-15P

Adapter for 240V/20A With NEMA 6-50P

Art # A-09274

CAUTION

When using the 120V/15A adapter cord, do not exceed a current output setting of 20Amps on the power supply
or the input power circuit breaker may trip.

Input Voltage

Rated Output

Amps (RMS) input at rated
output, 60 Hz, single-phase

kVA

120V, 15A Circuit

20A, 88V

18

2.2

120V, 20A Circuit

28A, 90V

26

3.1

120V, 30A Circuit

30A, 92V

29

3.5

208-230V, 20A Circuit 30A, 92V

16-14

3.3