Power Supply Dimensions & Weight

Ventilation Clearance Requirements

15"

381 mm

12"

305 mm

24"

610 mm

45 lb / 20.4 kg

Art # A-07924_AB

6"

150 mm

24"

610 mm

6"

150 mm

6"

150 mm

Art # A-07925_AB

NOTE

Weight includes torch & leads, input power cord, and work cable with clamp.

CAUTION

Provide clearance for proper air flow through the power supply. Operation without proper air flow will inhibit
proper cooling and reduce duty cycle.

2.05 Input Wiring Specifications

CutMaster 39 Input Power Requirements

Input

Power Input Current Input

Suggested Sizes (See Notes)

Voltage

Freq.

(kVA)

(Amps)

Fuse (Amps) Wire (AWG) Wire (Canada)

(Volts)

(Hz)

1-Ph

1-Ph

1-Ph

1-Ph

1-Ph

120

50 / 60

3.6

29

35

12

12

208

50 / 60

3.5

16

20

12

12

230

50 / 60

3.4

14

20

12

12

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electric Code

NOTES

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.

The suggested sizes are based on flexible power cable with power plug installations.

Cable conductor temperature used is 167° F (75° C).

An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should
be used to minimize damage to Plasma Cutting, Welding or power distribution equipment.

NEVER use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.

Extension Cords

Extension cords must meet National Electric Code Guidelines (and OSHA Guidelines, where applicable). Exten-

sion cords must have the same rating as the service and must have a three-pronged plug.