TROUBLESHOOTING

SYMPTOM

POSSIBLE CAUSE

SOLUTION

Saw will not operate

Power lead not plugged in

Ensure that the power lead is connected to the power supply

Power fault, fuse or circuit breaker tripped

Check the power supply

Brushes worn or sticking

Disconnect power, open brush caps and ensure brushes move freely in
the holders. Check whether brushes require replacing as outlined in the
maintenance section.

Lead damaged

Use authorised service centre** to repair or replace the lead

Faulty switch

Use authorised service centre** to repair or replace the switch

Faulty motor

Use authorised service centre** to repair or replace the motor

Poor performance

Extension lead too long or undersized

Use extension lead heavy enough to carry the current

Blunt or damaged blade

Re-sharpen or replace blade

Motor is overloaded

Reduce pushing force on saw. Ensure the cut isn’t closing and pinching the
blade.

Tool is overheating

Turn off the tool and let it cool down to room temperature. Inspect and clean the
ventilation slots.

Vibration or abnormal noise

Accessory not secured

Ensure that the saw blade is fully tightened in the arbor washers

Moving parts excessively worn

Use authorised service centre** to repair or replace

Mechanical obstruction

Use authorised service centre** to repair or replace

Armature has shorted sections

Use authorised service centre** to repair or replace

Motor runs but blade won’t spin

Blade retaining nut is loose

Tighten blade retaining nut, ensure the arbor washers are correctly fitted

Broken gear shaft or teeth

Use authorised service centre** to repair or replace

Saw depth adjustment not holding

Depth adjustment lever requires tightening

Reposition the depth adjustment lever as described in 'Adjusting the depth
locking lever tension'

Heavy sparking occurs inside motor
housing

Brushes not moving freely

Disconnect power, remove brushes, clean or replace

Armature short circuited or open circuited

Use authorised service centre** to repair or replace

Commutator surface not clean

Use authorised service centre** to repair or replace

Retractable guard will not close, or is
slow to close

Return spring detached or broken

Re-attach or replace spring (use only genuine Triton replacement parts)

Guard is bent

Straighten it or contact authorised service centre** to repair or replace

Mechanism fouled by sawdust

Clean and lightly lubricate fouled mechanism