Injector Cap, Screen, Injector Plug and Injector

The screen, injector and/or injector plug(s) are installed under the injector cap in an easy to access location on top of the valve. The
injector cap contains four slots so no water accumulates in the cap. The injector cap is designed to be hand tightened.

Under the injector cap there is an easy to clean removable screen to prevent fouling of the injector. There are two holes under the
injector cap labeled “DN” and “UP”. The holes will be filled with a plug or an injector.

The plug (Order # V3010-1Z) prevents water from traveling a certain pathway. The injector lets water pass through the pathway.
The self-priming injector increases the velocity of the water, creating a zone of negative pressure that draws in the concentrated
liquid regenerant, such as sodium chloride (brine), potassium permanganate, etc. The regenerant blends with the stream of water,
which passes through the media to regenerate the bed.

The injector provides a consistent regenerant/water mixture ratio over the entire operating pressure range of the control valve. The
injector provides good performance in a variety of applications, which may involve elevated drain lines and long regenerant draw
lengths. Injectors are chosen by knowing the type, amount, and regenerant flow rate for a particular type of media. Guidelines can
be found in the media manufacturer’s literature. The color coded injectors give different regenerant draw, slow rinse and total flow
rates over the pressure range. See Table 4 for color codings, and injector graphs for total, slow rinse and draw flow rates.

The control valve has been designed so that the OEM can rapidly change the control valve to allow for the following options:

• regeneration downflow (for softeners or regenerating filters install injector in DN location, plug in UP location); or

• no regeneration (both the DN and UP holes have injector plugs installed) and plug installed for the refill elbow.

Refill Flow Control Assembly or Refill Port Plug

The refill flow control assembly consists of a refill flow elbow, refill flow control retainer assembly, refill flow control, polytube
insert and nut assembly. The refill flow control retainer fits in the refill elbow. The refill flow control retainer houses the refill flow
control which controls the flow rate when the regenerant tank is being refilled. The refill flow control is a flexible washer-like
part with a small orifice and a precision molded contour that delivers a steady 0.5 gpm regenerant tank refill rate at varying inlet
pressures. Refill is accomplished with treated water.

2

Actual tank size used may vary depending on the design and application of the system. Tank diameter is an approximation for a

downflow softener using standard mesh synthetic cation exchange media regenerating with sodium chloride.

Typical Tank Diameter

2

Injector Order Number

Injector Color

Downflow Brining

V3010-1A

Black

6"

V3010-1B

Brown

7"

V3010-1C

Violet

8"

V3010-1D

Red

9"

V3010-1E

White

10"

V3010-1F

Blue

12"

V3010-1G

Yellow

13"

V3010-1H

Green

14"

V3010-1I

Orange

16"

V3010-1J

Light Blue

18"

V3010-1K

Light Green

22"

Table 4

Injector Order Information