The user can initiate manual regeneration. The user has the option to request the manual regeneration at the delayed regeneration
time or to have the regeneration occur immediately. Simultaneously press the UP + DOWN buttons to start a regeneration at the
next delayed regeneration time. If a regeneration is to occur today an arrow will point to regeneration. For immediate regeneration,
simultaneously press and hold the UP + DOWN buttons for three seconds.
When in regeneration, step through the different regeneration cycles by simultaneously pressing the UP + DOWN buttons.
The control valve consists of the following components:
1. Drive Assembly
2. Drive Cap Assembly, Main Piston and Regenerant Piston
3. Spacer Stack Assembly
4. Injector Cap, Screen, Injector Plug and Injector
5. Refill Flow Control Assembly or Refill Port Plug
6. Drain Line Flow Control and Fitting Assembly
7. Mixing Valve (optional)
8. Installation Fitting Assemblies
9. Bypass Valve (optional)
Note: The WS1TC & WS1.25TC share many of the same components. Refer to Figure 6 for control valve identification.