Model 9000/9100/9500

45

General Service Hints
Problem: Softener delivers hard water

PROBLEM

CAUSE

CORRECTION

8. Softener fails to draw brine.

A. Drain line flow control is plugged.
B. Injector is plugged.
C. Injector screen plugged.
D. Line pressure is too low.

E. Internal Control Leak

A. Clean drain line flow control.
B. Clean injector.
C. Clean screen.
D. Increase line pressure to

25 psi min.

E. Change seals, spacers and piston

assembly.

9. Control cycles continuously.

A. Broken or shorted switch.

A. Determine if switch or timer is

faulty and replace it, or replace

complete power head.

10.Drain flows continuously.

A. Valve is not programming correctly.

B. Foreign material in control.

C. Internal control leak.

A. Check timer program and positioning

of control. Replace power head

assembly if not positioning properly.

B. Remove power head assembly and

inspect bore, remove foreign

material and check control in various

regeneration positions.

C. Replace seals and piston assembly.

PROBLEM

CAUSE

CORRECTION

Softener delivers hard water.

Reserve capacity has been exceeded. Check salt dosage requirements and

reset program wheel to provide addi-
tional reserve.

Program wheel is not rotating with
meter output.

Pull cable out of meter cover and rotate
manually. Program wheel must move
without binding and cycle actuator must
start the cycle before the clutch
releases.

Meter is not measuring flow.

Check output by observing rotation of
small gear on front of timer

(Note: Program wheel must not be
against regeneration stop for this check)

Each tooth is approximately 75 gallons
on 1-1/2

″ installations. If not performing

properly, replace meter.