The RO feed water must be pretreated in order to prevent mem-

brane damage and/or fouling. Proper pretreatment is essential for

reliable operation of any RO system.
Pretreatment requirements vary depending on the nature of the feed

water. Pretreatment equipment is sold separately. The most common

forms of pretreatment are described below.
Media Filter - Used to remove large suspended solids (sediment)

from the feed water. Backwashing the media removes the trapped

particles. Backwash can be initiated by time or differential pressure.
Water Softener - Used to remove calcium and magnesium from

the feed water in order to prevent hardness scaling. The potential

for hardness scaling is predicted by the Langelier Saturation Index

(LSI). The LSI should be zero or negative throughout the unit unless

approved antiscalents are used. Softening is the preferred method of

controlling hardness scale.
Carbon Filter - Used to remove chlorine and organics from the

feed water. Free chlorine will cause rapid irreversible damage to the

membranes.
The residual free chlorine present in most municipal water supplies

will damage the thin film composite structure of the membranes

used in this unit. Carbon filtration or sodium bisulfite injection should

be used to completely remove the free chlorine residual.
Chemical Injection - Typically used to feed antiscalant, coagulant,

or bisulfite into the feed water or to adjust the feed water pH.
Prefilter Cartridge - Used to remove smaller suspended solids and

trap any particles that may be generated by the other pretreatment.

The cartridge(s) should be replaced when the pressure drop across

the housing increases 5 - 10 psig over the clean cartridge pressure

drop. The effect of suspended solids is measured by the silt density

index (SDI) test. An SDI of five (5) or less is specified by most mem-

brane manufacturers and three (3) or less is recommended.
Iron & Manganese - Iron should be removed to less than 0.1 ppm.

Manganese should be removed to less than 0.05 ppm. Special me-

dia filters and/or chemical treatment is commonly used.
pH - The pH is often lowered to reduce the scaling potential. If the

feed water has zero hardness, the pH can be raised to eliminate

CO2.
Silica: Reported on the analysis as SiO2. Silica forms a coating on

membrane surfaces when the concentration exceeds its solubility.

Additionally, the solubility is highly pH and temperature dependent.

Silica fouling can be prevented with chemical injection and/or reduc-

tion in recovery.

2

I. Introduction

The separation of dissolved solids and water using RO membranes

is a pressure driven temperature dependent process. The membrane

material is designed to be as permeable to water as possible, while

maintaining the ability to reject dissolved solids.
The main system design parameters require the following:
• Internal flows across the membrane surface must be high enough

to prevent settling of fine suspended solids on the membrane

surface.

• The concentration of each dissolved ionic species must not exceed

the limits of solubility anywhere in the system.

• Pre-treatment must be sufficient to eliminate chemicals that would

attack the membrane materials.

PWR25111011 PWR25112011 PWR25113011 PWR25113021

Maximum Productivity

(gallons per day)

150

250

600

1200

Quality

(membrane rejection)

98 %

98 %

98 %

98 %

Recovery

(user adjustable)

15 - 75 %

15 - 75%

15 - 75 %

30 - 75 %

Membrane Size

2.5" x 14"

2.5" x 21"

2.5" x 40"

2.5" x 40"

Number Of Membranes

1

1

1

2

Dimensions W x H x D

(approximate inches)

22 x 32 x 12

22 x 52 x 12

Prefilter

(system ships with one

5 micron cartridge)

10"

Feed Water Connection

1

2

" NPT

Product Water

Connection (tubing OD)

3

8

"

Reject Water

Connection (tubing OD)

3

8

"

Feed Water Required

(maximum)

2.4 gpm

Feed Water Pressure

(minimum)

20psi

Drain Required

(maximum)

2.4 gpm

Electrical Requirement

120 VAC 60 Hz 8 amps

Motor Horse Power

1

2

Shipping Weight

(estimated pounds)

50

50

60

70

Notes:
• Maximum production based on a feed water of 77°F, SDI < 3, 1000 ppm TDS,

and pH 8.

Individual membrane productivity may vary (± 15%). May be operated on other
feed waters with reduced capacity.
• Percent Rejection is based on membrane manufactures specifications; overall

system percent rejection may be less.

A. Specifications

RO Membrane

Feed Water

Product Water

Reject Water

B. RO Overview

Reverse osmosis systems utilize semipermeable membrane ele-

ments to separate the feed water into two streams. The pressurized

feed water is separated into purified (product) water and concentrate

(reject) water. The impurities contained in the feed water are carried

to drain by the reject water. It is critical to maintain adequate reject

flow in order to prevent membrane scaling and/or fouling.