Model 2900s - upflow – Watts Fleck 2900 Brass Valve User Manual
Page 44
Page 44
MODEL 2900s - Upflow
1
SERVICE POSITION
2
BRINE POSITION
3
SLOW RINSE POSITION
Hard water enters unit at valve inlet and flows down thru the mineral in the mineral tank. Condi-
tioned water enters center tube thru the bottom distributor — then flows up thru the center tube —
around the piston and out the top outlet of the valve.
Hard water enters unit at valve inlet — flows up into injector housing
and down thru nozzle and orifice to draw brine from the brine tank —
brine flows down the center tube thru bottom of tank, up thru mineral to
top of tank, around piston and out thru the drain line.
Hard water enters unit at valve inlet — flows up into injector
housing and down thru nozzle and orifice — around the piston — down
thru center tube thru bottom distributor — flows up thru mineral —
around piston and out thru the drain line.