Month system maintenance annual maintenance – Watts PWROKCZRO User Manual
Page 7
7
Order filter by calling Watts at 1-800-224-1299
Item Needed: EDP# 7100109
Includes:
• (1) Carbon Block Filter
This reverse osmosis system contains a replaceable compo-
nent (the RO membrane) which is critical to the efficiency of the
system. Replacement of this reverse osmosis membrane should
be with one of identical specifications as defined by Watts to
assure the same efficiency and contaminant reduction perfor-
mance.
Note: Your RO module is equipped with valved heads which will
automatically turn off the water supply to each filter when the
filter is released, thus you do not need to turn off the incoming
water supply at the Adapt-A-Valve™. The faucet must be off
when filter is replaced.
Step A – Place the towel under the RO module to catch any excess
water that drips out from the filters during the changeover .
Step B – To make the removal of the
filter housings easier, the heads
& housings may be lifted up
to 90 degrees as shown in the
pictures to the right . Starting
with cartridge closest to the
pump . Change only the carbon
block filter, lift the cartridge
up to 90 degrees . Rotate the cartridge a
1
⁄
4
turn counter-
clockwise, remove and dispose of used cartridge .
Step C – Make sure to remove the
cap off of the new replace-
ment filter . Insert the new filter
cartridge into the head and
rotate it clockwise
1
⁄
4
turn until
it stops . Return cartridge to the
vertical position .
Step D – When finished flush your tank
completely once to remove
any natural carbon fines from
the RO system . Check over
the next 24 hours to ensure no
leaks are present .
Photographs for reference purposes
only for Kwik-Change™ drinking water
systems . Your system may contain 2, 3,
or 4 filter cartridges .
6-Month System Maintenance
Annual Maintenance
Order filter by calling Watts at 1-800-224-1299
Item Needed: # 7100119
Includes:
• (1) Carbon Block Filters
• (1) Membrane
• (1) Post GAC
Note: Your RO module is equipped with valved heads which will
automatically turn off the water supply to each filter when the
filter is released, thus you do not need to turn off the incoming
water supply at the Adapt-A-Valve™. The faucet must be off
when filters are replaced.
Step A – Place the towel under the RO module to catch any excess
water that drips out from the filters during the changeover .
Step B – Start with Carbon Block Filter
(closest to pump) . Lift the
cartridge to make the removal
of the filter housings easier, the
heads & housings may be lifted
up to 90 degrees as shown
in the pictures to the right .
Starting with the sediment filter,
lift the cartridge up to 90 degrees . Rotate the cartridge
a
1
⁄
4
turn counterclockwise, remove and dispose of used
cartridge .
Step C – Make sure to remove the
cap off of the new replace-
ment filter . Insert the new filter
cartridge into the head and
rotate it clockwise
1
⁄
4
turn until
it stops . Return cartridge to the
vertical position .
Step D – Repeat this procedure for the
2nd and 3rd filter cartridges .
When finished flush your tank
completely once to remove
any natural carbon fines from
the RO system . Check over
the next 24 hours to ensure no
leaks are present .
Photographs for reference purposes
only for Kwik-Change™ drinking water
systems . Your system may contain 2, 3,