beautypg.com

Troubleshooting – Watts PWROKCZRO User Manual

Page 10

background image

10

probleM

cause

solution

1. Low/Slow Production

Low Water Pressure

Assure a minimum of 40psi incoming water pressure.

Watts sells a booster pump if home water pressure is low.

Make sure water supply is turned on and Adapt-A-Valve™ is

all the way open.

Crimps in tubing

Check tubing and straighten or replace as necessary.

Clogged pre-filters

Replace pre-filters.

Fouled membrane

Replace membrane and flow restrictor.

2. Milky colored Water

Air in system

Air in the system is a normal occurrence with initial start up

of the RO system. This milky look will disappear during normal

use within 1-2 weeks. If condition reoccurs after filter change,

drain tank 1 to 2 times.

3. Water constantly running, unit will not shut off

Low water pressure

See #1 Above

Crimp in supply tube

Check tubing and straighten or repair as necessary.

4. Noise / Water from faucet vent hole or noise from in drain

line drain.

Crimp or restriction

Check tubing and straighten or repair as necessary.

Straighten all drain lines. Clear blockage. Cut off any Excess

tubing

Drain tube clogged

Caused from dishwasher or garbage disposal.

Disconnect the 3/8" black line at the drain, clean the 3/8"

black line out with a wire, then reconnect. Blowing air through

the line will not always remove the clog.

5. Small amount of water in storage tank

System starting up

Normally it takes 4-6 hours to fill tank. Note: low incoming

water pressure and/or temperature can drastically reduce

production rate.

Low water pressure

See #1 above.

To much air in tank

Tank air pressure should be 5-7psi when empty of water.

If below 5psi, add air or bleed if above 7psi.

Check only when tank is empty of water. See previous page.

6. Water leaks from the filter membrane housing

Not properly tightened

Re-insert the filter / membrane housing.

7. Low water flow from faucet

Check air pressure in tank

Use a Digital Air Gauge for best results. The empty tank pres-

sure should be 5-7 psi. To reset the air pressure in the tank,

turn off water supply and drain tank by opening faucet. When

water stops flowing out of the faucet. Remove schrader valve

cover pump air into tank until water stops flowing from the

faucet. Release the air out of the schrader valve until you

reach 5-7 psi. Replace schrader valve cover. Turn on Water.

Troubleshooting