Troubleshooting – Watts PWROKCZRO User Manual
Page 10
![background image](/manuals/589421/10/background.png)
10
probleM
cause
solution
1. Low/Slow Production
Low Water Pressure
Assure a minimum of 40psi incoming water pressure.
Watts sells a booster pump if home water pressure is low.
Make sure water supply is turned on and Adapt-A-Valve™ is
all the way open.
Crimps in tubing
Check tubing and straighten or replace as necessary.
Clogged pre-filters
Replace pre-filters.
Fouled membrane
Replace membrane and flow restrictor.
2. Milky colored Water
Air in system
Air in the system is a normal occurrence with initial start up
of the RO system. This milky look will disappear during normal
use within 1-2 weeks. If condition reoccurs after filter change,
drain tank 1 to 2 times.
3. Water constantly running, unit will not shut off
Low water pressure
See #1 Above
Crimp in supply tube
Check tubing and straighten or repair as necessary.
4. Noise / Water from faucet vent hole or noise from in drain
line drain.
Crimp or restriction
Check tubing and straighten or repair as necessary.
Straighten all drain lines. Clear blockage. Cut off any Excess
tubing
Drain tube clogged
Caused from dishwasher or garbage disposal.
Disconnect the 3/8" black line at the drain, clean the 3/8"
black line out with a wire, then reconnect. Blowing air through
the line will not always remove the clog.
5. Small amount of water in storage tank
System starting up
Normally it takes 4-6 hours to fill tank. Note: low incoming
water pressure and/or temperature can drastically reduce
production rate.
Low water pressure
See #1 above.
To much air in tank
Tank air pressure should be 5-7psi when empty of water.
If below 5psi, add air or bleed if above 7psi.
Check only when tank is empty of water. See previous page.
6. Water leaks from the filter membrane housing
Not properly tightened
Re-insert the filter / membrane housing.
7. Low water flow from faucet
Check air pressure in tank
Use a Digital Air Gauge for best results. The empty tank pres-
sure should be 5-7 psi. To reset the air pressure in the tank,
turn off water supply and drain tank by opening faucet. When
water stops flowing out of the faucet. Remove schrader valve
cover pump air into tank until water stops flowing from the
faucet. Release the air out of the schrader valve until you
reach 5-7 psi. Replace schrader valve cover. Turn on Water.