beautypg.com

Watts PWROKCZRO User Manual

Page 4

background image

4

How To Use the Quick-Connect Fittings For Tubing Connections

To make a connection, the tube is simply pushed into the fitting .

Place a piece of tape

1

2

" from end of tube to indicate how far the

tube should be inserted . The unique patented locking system holds

the tube firmly in place without deforming it or restricting flow .

NOTE: These diagrams are just to show how the quick-connect

fittings work, your product may not have this exact connector

part.

It is essential that the outside diameter be free of score marks and that burrs and

sharp edges be removed before inserting into fitting .

Fitting grips before it seals. Ensure tube is pushed into the tube stop.

Push the tube into the fitting, to the tube stop . The collet (gripper) has stainless

steel teeth which hold the tube firmly in position while the O-ring provides a perma-

nent leak proof seal .

Pull on the tube to check that it is secure . It is a good practice to test the system

prior to leaving site and /or before use .

To disconnect, ensure the system is depressurized before removing the tube . Push

in collect squarely against face of fitting . With the collet held in this position, the

tube can be removed . The fitting can then be reused .