beautypg.com

Month system maintenance, Annual maintenance – Watts PWRO4 User Manual

Page 8

background image

8

Step E – Clean the filter housings (bowls)

with a mild soap solution and

rinse with water . Check O-rings

and lubricate with water soluble

lubricant. KY Jelly

®

, canola oil

or other water based lubricants

may be used . Petroleum

based lubricants (such as

Vaseline

®

) must not be used.

Caution: Before re-installing the filter bowls back on to the sys-

tem, check O-rings to make sure they are still in place.
Do not over-tighten filter housing, overtightening may damage

O-ring(s), cause water leaks, or affect system performance.
Step F – Insert a new sediment filter

(cloth like appearance) into

the 1st filter housing which is

the one on the water inlet side

(green tubing from the Adapt-

A-Valve™) of the RO system,

and re-install housing .

Step G – Insert the new Carbon Block

filter (White end caps & plastic netting) into the second and

third filter bowls and re-install housings .

Step H – Turn water supply on to the unit by turning the knob on the

Adapt-A-Valve™ counterclockwise .

Step I – Open the RO faucet and leave it open until water begins to

trickle out . (It will come out slowly) .

Step J – Close the RO faucet allowing the storage tank to fill with

water . It may take 4 to 6 hours to fill the tank completely

depending on the production capability of the membrane,

local water temperature and water pressure .

6-Month System Maintenance

Order filter by calling Watts at 1-800-224-1299
Item Needed: EDP# 7100110

Includes:

• (1) Sediment Filter

• (1) Carbon Block Filter

Step A – Turn off the incoming water supply to the RO by turning the

knob on the Adapt-A-Valve™ clockwise until it stops .

Step B – Open the RO Faucet and allow water to drain from the tank

until it is completely empty .

Note: Water may be saved in a container for drinking or to rinse

system parts.
Step C – Let system sit for 10 to 15

minutes after the tank is empty

to let the system depressurize

before attempting to remove

filter housings .

Step D – For more leverage you may

leave the RO module attached

to wall of cabinet . If you are

unable to access the module

while it is mounted, remove it

prior to changing filters . Start-

ing with the closest housing

(Stage 1), remove it by turning

it clockwise (left), empty water,

then discard filter . Continue on

to the 2nd housing (Stage 2)

and 3rd housing (Stage 3) .

Note: If you own a 4-stage system it will not have the third

stage. A 4-stage system has two vertical housings instead of

three.

Annual Maintenance

Order filter by calling Watts at 1-800-224-1299
Item Needed: # 7100110, 7100120, 7100454

1/2 cup of hydrogen peroxide or household bleach .

Includes:

• (1) Sediment Filter

• (1) Membrane

• (1) Carbon Block Filters

• (1) Final In-Line Filter

Note: Sanitizing of unit is recommended.
Step A – Perform steps A through E in the Six Month System Main-

tenance .

Note: If not sanitizing the system skip to step H.
Step B – Remove the RO membrane from its housing and rest in a

clean sanitary place . (Refer to “Membrane Replacement”

section on Page 9 for directions on removing the mem-

brane) . Replace cap onto empty membrane housing and

re-connect green tubing .

Step C – Leaving the filters out, replace Stage 1 and 2 empty filter

housings (hand tight) onto unit . Measure & pour either

1

2

cup of hydrogen peroxide or common household bleach

into the 1st filter housing (Stage 1) and hand tighten onto

unit .

Note: Overtightening components can damage the system

causing water damage and/or system failure.
Step D – With the RO faucet in the closed position turn on the

incoming water supply to the system by turning the Adapt-

A-Valve™ counterclockwise . Wait 1 minute for the unit to

pressurize . Turn on the RO faucet, and let the water run for

30 seconds . Turn off the RO faucet, and let the unit rest for

2 minutes . Finally, open the RO faucet, and let the water

run for 5 more minutes .

Step E – Turn off the incoming water supply to the system by turning

the Adapt-A-Valve™ clockwise until it stops. Keep the RO

faucet open until the storage tank is completely drained .

Step F – Open the membrane housing and re-install the RO mem-

brane while making sure not to kink the O-rings . (Refer to

“Membrane Replacement” section on Page 9 for directions

on installing the membrane) . Tighten the cap back on the

housing and reconnect green tubing .

Step G – Remove filter housings Stage 1 and 2 and empty of water .
Caution: Before re-installing the filter bowls back on to the

system , check O-rings to make sure they are still in place and

lubricate with water soluble lubricant.
Do not over-tighten filter housing, overtightening may damage

O-ring(s), cause water leaks, or affect system performance.
Step H – Insert the new Sediment Filter (cloth like appearance) into

the 1st filter housing which is the one on the water inlet

side (green tubing from the Adapt-A-Valve™) of the RO

system and re-install housing .

Step I – Insert the new Carbon Block filter (White End Caps) into the

2nd housing and re-install housing .

Step J – The Final In-Line filter is located on the blue tube between

the storage tank and the RO faucet . Remove it by loosen-

ing the compression fittings on both ends of the filter and

replace with new filter . (Discard used final filter after sanitiz-

ing)

Note: The arrow on the final filter must be pointing towards the

RO faucet / away from the RO storage tank.
This is a good time to check the air pressure in your storage

tank. For instructions please see Page 9.
Step K – Follow Steps H through J in the 6-Month System Mainte-

nance (Page 7) for startup directions .