M12 series metal barrel sensors, Performance curves, Excess gain beam pattern opposed polarized retro – Banner M12 Series—Visible Red LED User Manual
Page 5: Retro, Diffuse, Excess gain fixed-field – 25 mm, Fixed-field – 50 mm fixed-field – 75 mm

P/N 129721 rev. E
5
Banner Engineering Corp. • Minneapolis, MN U.S.A
www.bannerengineering.com • Tel: 763.544.3164
M12 Series Metal Barrel Sensors
Performance Curves
Excess Gain
Beam Pattern
Opposed
Polarized
Retro
††
Retro
††
Diffuse
Performance based on use of 90% reflectance white test card.
Excess Gain
Fixed-Field
–
25
mm
Performance based on use of 90% reflectance white test card.
†
Fixed-Field
–
50
mm
Fixed-Field
–
75
mm
(16")
(16")
(8")
(8")
(24")
(24")
5 m
(16')
4 m
(13')
3 m
(9.8')
2 m
(6.6')
1 m
(3.3')
0
-200 mm
-400 mm
-600 mm
200 mm
400 mm
600 mm
DISTANCE
Beam Width
M12
Opposed
0
0
M12
Opposed
DISTANCE
1000
10000
10
100
0.1 m
(0.3')
1.0 m
(3.0')
10.0 m
(30.0')
0.01 m
(.03')
1
E
X
C
E
S
S
G
A
I
N
††
Performance based on use of a model BRT-84 retroreflector.
Focus and spot sizes are typical.
M12
Diffuse
DISTANCE
1000
10
100
10 mm
(0.4")
100 mm
(4.0")
1000 mm
(40.0")
1 mm
(.04")
1
E
X
C
E
S
S
G
A
I
N
(0.4")
(0.4")
(0.2")
(0.2")
(0.6")
(0.6")
500 mm
(20")
400 mm
(16")
300 mm
(12")
200 mm
(8")
100 mm
(4")
0
-5 mm
-10 mm
-15 mm
5 mm
10 mm
15 mm
DISTANCE
Beam Width
M12
Diffuse
0
0
Ø 2 mm spot size @ 25 mm focus
Ø 2 mm spot size @ 25 mm cutoff
†
Using 18% gray test card: cutoff distance
will be 96% of value shown.
†
Using 6% black test card: cutoff distance
will be 94% of value shown.
(0.8")
(0.8")
(0.4")
(0.4")
(1.2")
(1.2")
(1.6")
(1.6")
2.0 m
(6.5')
1.6 m
(5.2')
1.2 m
(3.9')
0.8 m
(2.6')
0.4 m
(1.3')
0
-10 mm
-20 mm
-30 mm
-30 mm
10 mm
20 mm
30 mm
40 mm
DISTANCE
Beam Width
M12
Polarized Retro
0
0
(1.6")
(1.6")
(0.8")
(0.8")
(2.4")
(2.4")
(3.1")
(3.1")
2.5 m
(8.2')
2 m
(6.6')
1.5 m
(4.9')
1 m
(3.3')
0.5 m
(1.6')
0
-20 mm
-40 mm
-60 mm
-80 mm
20 mm
40 mm
60 mm
80 mm
DISTANCE
Beam Width
M12
Retroreflective
0
0
Ø 2 mm spot size @ 25 mm focus
Ø 7 mm spot size @ 50 mm cutoff
†
Using 18% gray test card: cutoff distance
will be 90% of value shown.
†
Using 6% black test card: cutoff distance
will be 85% of value shown.
Ø 2 mm spot size @ 25 mm focus
Ø 13 mm spot size @ 75 mm cutoff
†
Using 18% gray test card: cutoff distance
will be 80% of value shown.
†
Using 6% black test card: cutoff distance
will be 70% of value shown.
M12
Retroreflective
DISTANCE
1000
10
100
0.1 m
(0.3')
1 m
(3.3')
10 m
(33')
0.01 m
(0.03')
1
E
X
C
E
S
S
G
A
I
N
M12
Polarized Retro
DISTANCE
1000
10
100
0.1 m
(0.3')
1 m
(3.3')
10 m
(33')
0.01 m
(0.03')
1
E
X
C
E
S
S
G
A
I
N
M12
Fixed Field - 25 mm
DISTANCE
1000
10
100
10 mm
(0.4")
100 mm
(4.0")
1000 mm
(40.0")
1 mm
(.04")
1
E
X
C
E
S
S
G
A
I
N
M12
Fixed Field - 50 mm
DISTANCE
1000
10
100
10 mm
(0.4")
100 mm
(4.0")
1000 mm
(40.0")
1 mm
(.04")
1
E
X
C
E
S
S
G
A
I
N
M12
Fixed Field - 75 mm
DISTANCE
1000
10
100
10 mm
(0.4")
100 mm
(4.0")
1000 mm
(40.0")
1 mm
(.04")
1
E
X
C
E
S
S
G
A
I
N