Sensor Programming
Two TEACH methods may be used to program the sensor, using the TEACH button:
•
Teach individual minimum and maximum limits.
•
Use the Auto-Window feature to center a sensing window around the taught position.
A
B
C
D
E
F
Figure 3. Sensor features
A - TEACH button
B - Sensor power indicator
C - Target signal strength indicator
D - Speed button
E - Output response time indicator
F - Output ON indicator
Teaching Minimum and Maximum Limits
Output OFF
Output ON
Output OFF
Minimum
Limit
Maximum
Limit
Output ON
Output ON
Output OFF
Minimum
Limit
Maximum
Limit
Normally Closed Output
Normally Open Output
Figure 4. Teaching independent minimum and maximum limits —
window limit models
Teach procedures are identical for window-limit and fill-
level control models. Window-limit models function as
shown in the figure on the right, and fill-level control
on page 5. To
readjust minimum or maximum limits, repeat the teach
procedure.
A button click is defined as: 0.04 s. ≤ Click ≤ 0.8 s.
1. Enter programming mode.
Action
Result
Push and hold TEACH button for 2 seconds
Output LED turns solid red and the sensor waits for first limit
2. Teach the first limit.
Action
Result
Position the target for the first limit.
Click the TEACH button.
The sensor learns the first limit position and the Output LED
changes to flashing red
3. Teach the second limit.
U-GAGE QT50UVR Series Sensors
4
www.bannerengineering.com - tel: 763-544-3164
P/N 117764 Rev. F