S2 series, Product specifications – Banner T30 Series User Manual
Page 5

S2 Series
Banner Engineering Corporation
page
5
Product Specifications
Supply Voltage and Current
Opposed Mode Emitter
Opposed Mode Receiver
Polarized Retro
Fixed-field
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
Sensing Output: PNP (current sourcing), light operated
Output Rating
150 mA maximum (each); the total load may not exceed 150 mA;
Off-state leakage current <1 microamp at 30V dc;
On-state saturation voltage <1V at 10 mA dc; <1.5V at 150 mA dc
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or short-circuit of outputs
Output Response Time
Opposed: 3 milliseconds "on" and 1.5 milliseconds "off"
Polarized Retro and Fixed-field: 3 milliseconds "on" and "off"
NOTE: 100 millisecond delay on power-up; outputs are non-conducting during this time
Indicators
Two LEDs: Green and Yellow
GREEN glowing steadily
= power to sensor is "on"
GREEN flashing
= output is overloaded
YELLOW glowing steadily = normally open output is conducting
YELLOW flashing
= excess gain marginal (1-1.5x) in light condition
Repeatability
Opposed: 375 microseconds
Polarized Retro and Fixed-field: 750 microseconds
Repeatability and response are independent of signal strength
Construction
Housings are VALOX
®
thermoplastic polyester; Lenses are Lexan
®
(opposed models) or acrylic (retro and fixed-
field models) S18 and S30 come with two jam nuts; T18, T30, Q25 and Q40 come with one jam nut
Environmental Rating
Leakproof design rated NEMA 6P; IEC IP67
Connections
4-pin euro-style quick-disconnect fitting; cables are ordered separately
Operating Temperature
-40° to +70°C (-40° to 158°F); Maximum relative humidity 90% at 50°C (non-condensing)
Vibration and
Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max.,
double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit
operating; 100G for non-operation)
10 to 30V dc (10% maximum ripple); Supply current (exclusive of load current):
25 mA
20 mA
30 mA
35 mA
Alarm Output: PNP (current sourcing), normally open
and conducts whenever the sensor's excess gain drops
to between 1X and 1.5X in the light condition