S2 series, Fixed-field mode, 50 mm far limit cutoff – Banner T30 Series User Manual
Page 4: 100 mm far limit cutoff, 200 mm far limit cutoff, 400 mm far limit cutoff

page
4
Banner Engineering Corporation
S2 Series
Fixed-field Mode
Models
Range
Cable
Supply
Voltage
Output
Type
Excess Gain
Performance based on 90% reflectance white test card
50 mm far limit cutoff
S18S2P6FF50Q
50 mm
(2 in)
4-Pin Euro QD
10-30V dc
PNP
Q25S2P6FF50Q
T18S2P6FF50Q
100 mm far limit cutoff
S18S2P6FF100Q
100 mm
(4 in)
4-Pin Euro QD
10-30V dc
PNP
Q25S2P6FF100Q
T18S2P6FF100Q
200 mm far limit cutoff
S30S2P6FF200Q
200 mm
(8 in)
4-Pin Euro QD
10-30V dc
PNP
Q40S2P6FF200Q
T30S2P6FF200Q
400 mm far limit cutoff
S30S2P6FF400Q
400 mm
(16 in)
4-Pin Euro QD
10-30V dc
PNP
Q40S2P6FF400Q
T30S2P6FF400Q
1
10
100
1 mm
.04 in
10 mm
.4 in
100 mm
4 in
.1 mm
.004 in
E
X
C
E
S
S
G
A
I
N
DISTANCE
1000
S18, Q25 and T18 Series
Fixed-field mode
with 50 mm far
limit cutoff
1
10
100
1 mm
.04 in
10 mm
.4 in
100 mm
4 in
.1 mm
.004 in
E
X
C
E
S
S
G
A
I
N
DISTANCE
1000
Fixed-field mode
with 100 mm far
limit cutoff
S18, Q25 and T18 Series
1
10
100
10 mm
.4 in
100 mm
4 in
1000 mm
40 in
1 mm
.04 in
E
X
C
E
S
S
G
A
I
N
DISTANCE
1000
Fixed-field mode
with 200 mm far
limit cutoff
S30, Q40 and T30 Series
1
10
100
10 mm
.4 in
100 mm
4 in
1000 mm
40 in
1 mm
.04 in
E
X
C
E
S
S
G
A
I
N
DISTANCE
1000
Fixed-field mode
with 400 mm far
limit cutoff
S30, Q40 and T30 Series