Installation, Electrical connection – Blodgett RE Series User Manual
Page 11
![background image](/manuals/58729/11/background.png)
Installation
7
Electrical Connection
Before making any electrical connections to this
unit, check the rating plate located on the oven
control panel. Make sure the oven is being conĆ
nected to the proper electrical supply.
The supply conduit is connected to the junction
box located at the right rear corner of the oven.
ELECTRICAL SPECIFICATIONS
KW/Section
Voltage
HZ
Phase
Amperage
Electrical
Connection
KW/Section
Voltage
HZ
Phase
L1
L2
L3
Connection
AWG
21
208
60
1
103
-
103
1
21
208
60
3
58
56
57
4
21
220Ć240
60
1
89
-
89
2
21
220Ć240
60
3
51
53
51
6
21
460Ć480
60
3
26
26
26
8
NOTE: Use 75_C copper wire.