Installation

7

Electrical Connection

Before making any electrical connections to this

unit, check the rating plate located on the oven

control panel. Make sure the oven is being conĆ

nected to the proper electrical supply.

The supply conduit is connected to the junction

box located at the right rear corner of the oven.

ELECTRICAL SPECIFICATIONS

KW/Section

Voltage

HZ

Phase

Amperage

Electrical

Connection

KW/Section

Voltage

HZ

Phase

L1

L2

L3

Connection

AWG

21

208

60

1

103

-

103

1

21

208

60

3

58

56

57

4

21

220Ć240

60

1

89

-

89

2

21

220Ć240

60

3

51

53

51

6

21

460Ć480

60

3

26

26

26

8

NOTE: Use 75_C copper wire.