Metrohm 768 KF Oven User Manual
Page 24

3.2 Remote control commands
768 KF Oven
21
│
&
Root
│
Info
Information
│
│
.Report
Sending of formatted reports
$G
3.2.2.17
│
│
│
.Select
Selection of the report
configuration,
│
│
│
parameters,
│
│
│
result
3.2.2.18
│
│
.Results
Results of the determination
│
│
│
.PurgeTime
Purge time
read only
3.2.2.19
│
│
│
.CondTime
Conditioning time
read only
3.2.2.19
│
│
│
.SmplHeatTime
Sample heating time
read only
3.2.2.19
│
│
│
.LowTemp
Lowest temp. during heating
read only
3.2.2.19
│
│
│
.HighTemp
Highest temp. during heating
read only
3.2.2.19
│
│
│
.GasFlow
Mean gas flow
read only
3.2.2.19
│
│
│
.LowFlow
Lowest flow during heating
read only
3.2.2.19
│
│
│
.HighFlow
Highest flow during heating
read only
3.2.2.19
│
│
│
│
.ActualInfo
Current information
│
│
│
.Inputs
I/O lines, inputs
│
│
│
│
.Status
Status of the lines
read only
3.2.2.20
│
│
│
│
.Change
Change in the status of the lines read only
3.2.2.20
│
│
│
│
.Clear
Clears the change byte
read only
3.2.2.20
│
│
│
.Outputs
I/O lines, outputs
│
│
│
│
.Status
Status of the lines
read only
3.2.2.20
│
│
│
│
.Change
Changing the status of the lines read only
3.2.2.20
│
│
│
│
.Clear
Clears the change byte
read only
3.2.2.20
│
│
│
.Meas
Measured values
│
│
│
│
.CyclNo
Cycle number
read only
3.2.2.21
│
│
│
│
.SampleTemp
Sample temperature
read only
3.2.2.21
│
│
│
│
.OvenTemp
Oven temperature
read only
3.2.2.21
│
│
│
│
.GasFlow
Gas flow
read only
3.2.2.21
│
│
│
.Status
Status of the assemblies
│
│
│
│
.BoatPos
Position of the sample boat
read only
3.2.2.22
│
│
│
│
.Valve
Valve position
read only
3.2.2.22
│
│
│
│
.Pump
Pump
read only
3.2.2.22
│
│
│
│
.Heating
Heating power level
read only
3.2.2.22
│
│
│
.Display
Display
│
│
│
│
.L1
1st line
24 ASCII
3.2.2.23
│
│
│
│
.L2
2nd line
24 ASCII
3.2.2.23
│
│
│
│
.Assembly
Assembly
│
│
│
.CycleTime
Cycle time
read only
3.2.2.24
│
│
│
Assembly
Basic components of the assembly
│
│
.Prep
Perform preparations
$G, $S
3.2.2.25
│
│
.Heat
Heating on
$G
3.2.2.26
│
│
│
.Value
Heating power level
0...50
3.2.2.26
│
│
.Valve
Set valve position
$G
3.2.2.27
│
│
│
.Pos
Preselect position
purge, transfer
3.2.2.27
│
│
.Boat
Move sample boat
$G, $S
3.2.2.28
│
│
│
.Rate
Moving rate
0.1...10
3.2.2.28
│
│
│
.Pos
Go to position
0...130.0
3.2.2.28
│
│
│
.SetPos
Set stop points
│
│
│
│
.InPos
Inner stop
0...130.0
3.2.2.28
│
│
│
│
.OutPos
Outer stop
0...130.0v
3.2.2.28
│
│
.Pump
Switch pump on/off
$G, $S
3.2.2.29
│
│
.Outputs
I/O lines, outputs
│
│
│
.SetLines
Set lines
$G
3.2.2.30
│
│
│
│
.L1
Line 1
active, inactive
│
│
│
│
:
pulse, OFF
3.2.2.30
│
│
│
│
.L8
All lines as L1
│
│
│
.ResetLines
Set all lines inactive
$G
3.2.2.30