Troubleshooting
Symptom
Solution
Fixture Auto-
Shut Off
If it is stopped or dimmer than normal, the unit may have
shut itself off due to high heat. This is to protect the fixture
from overheating.
No Light Output Check to ensure fixture is operating under correct mode, IE
sound active/auto/DMX/Etc., if applicable.
Chase Speed
Too Fast/Slow
Check to ensure proper setup of speed adjustment.
No Power
Check fuse, AC cord and circuit for malfunction.
Blown Fuse
Check AC cord and circuit for damage, verify that moving
parts are not restricted and that unit’s ventilation is not
obstructed
Slow Movement Check that speed channels are set appropriately.
Fixture Not
Responding /
Responding Er-
ratically
Make sure all connectors are seated properly and securely.
Use Only DMX Cables and/or check cables for defects
Install a Terminator.
Reset fixture(s).
Fixture Moving
On Its Own
Verify proper mode of operation. Is the fixture in “Auto”
mode?
If your problem persists or isn’t listed, please contact us by
using our online support system: www.blizzardlighting.com/tickets.
DMX Values In-Depth (9-Channel Pixel Mode)
Ch. Value
What It Does
1
000 <--> 005
006 <--> 255
No Function
Segment 1 Intensity (0% <--> 100%)
2
000 <--> 005
006 <--> 255
No Function
Segment 2 Intensity (0% <--> 100%)
3
000 <--> 005
006 <--> 255
No Function
Segment 3 Intensity (0% <--> 100%)
4
000 <--> 005
006 <--> 255
No Function
Segment 4 Intensity (0% <--> 100%)
5
000 <--> 005
006 <--> 255
No Function
Segment 5 Intensity (0% <--> 100%)
6
000 <--> 005
006 <--> 255
No Function
Segment 6 Intensity (0% <--> 100%)
7
000 <--> 005
006 <--> 255
No Function
Segment 7 Intensity (0% <--> 100%)
8
000 <--> 005
006 <--> 255
No Function
Segment 8 Intensity (0% <--> 100%)
9
000 <--> 005
006 <--> 255
No Function
Segment 9 Intensity (0% <--> 100%)