Maintenance – Bird Technologies BA-310 Series User Manual
Page 22
Bird BA–300/310 Blower Assembly
12
Maintenance
Cleaning
The intake grills, fan, and inside surface of the baffles should be
wiped free of dust and dirt when necessary with a clean soft cloth.
Excessive dust will interfere with the efficient dissipation of heat. If
the BA–300/310 has been standing without an installed load, check
for objects that may have entered the blower openings.
When a load is installed on the blower assembly, it will be necessary
to partially disassemble the blower to clean the load’s radiator fins.
Follow the instructions below:
y
Remove one of the side baffles by unscrewing both 10-32 truss
head screws.
y
Clean the load.
y
Screw the baffle back into place.
Inspection
The only regular inspection required is to check for the accumulation
of dust in locations that might impede the free flow of air, i.e., intake
grill and fan blades. If the blower assembly is attached to a load,
clean the radiator fins regularly.
WARNING
Disconnect the unit from all power sources before servicing.
The unit may be energized from multiple sources.
The potential for electric shock exists.
WARNING
Do not operate with side panel removed.