Specifications, General – Bird Technologies ACMI User Manual
Page 43
![background image](/manuals/583879/43/background.png)
31
Specifications
General
Directivity, Min.
108 – 960 MHz
960 – 2400 MHz
30 dB
26 dB
VSWR Alarm Setpoint
1.3:1.0 to 2.5:1.0 by 0.1:1.0 steps.
Refer to "Power/Alarm Connector"
on page
7 for information about
power limitations.
Alarm Relays
Dry, form C. Common, normally
open, & normally closed contacts.
Relay Contact Rating
100 VDC @ 0.5 A
Visual Alarm
Red LED will light to indicate
an alarm
Alarm Stimulus
VSWR setpoint exceeded,
response time proportional to
overload
Alarm Reset
Local mechanical reset switch
Remote input (Reset if VDC =
0 to +0.8 V)
RF Connectors
Male or Female, N or 7/16 DIN
Monitor Port Connectors
Female N, TNC, or BNC
Monitor Port Coupling
–63 dB nominal
Passive Intermodulation
Products
< –130 dBc
Ethernet Port
Connector
Protocol
RJ-45
10/100 IEEE802.3
Power/Alarm Parallel Port
Female DB-15 connector
Power Requirements
ACMI-x-xxxxxL
ACMI500-x-xxxxxL
ACMI-x-xxxxxM
ACMI500-x-xxxxxM
ACMI-x-xxxxxH
ACMI500-x-xxxxxH
+/- (8 to 18) VDC @ 2.65 W
+/- (8 to 18) VDC @ 2.65 W
+/- (18 to 36) VDC @ 2.65 W
+/- (18 to 36) VDC @ 2.65 W
+/- (36 to 72) VDC @ 2.65 W
+/- (36 to 72) VDC @ 2.65 W
Analog Outputs
0 to 5 V full scale, 200 ohm
output impedance
Temperature
Operating
Storage
0 to 50 °C (32 to 122 °F)
–20 to +80 °C (–4 to +176 °F)
Altitude, Max.
3000 m (10,000 ft.)
Humidity, Max.
95% non-condensing
Dimensions, Nominal,
without connectors
4.75” L x 6.44” W x 1.22” H
(121 x 164 x 31 mm)
Weight, Max.
2 lbs. (0.9 kg)