23

No meter
indication
(PEAK only)

Faulty instrumentation
module

Replace the instrumentation module, see
“Replacing the Instrumentation Module” on
page 26.

Dead or low battery

Test battery. See “Battery Procedures” on
page 24. Repl
ace if neccesary. See
“Replacing the Batteries” on page 24.

If pointer does not move from zero during
the battery test, remove the batteries and
measure their voltage. If less than 6.25
volts, replace the batteries. See “Replacing
the Batteries” on page 24.

Erroneous or
inaccurate

Low battery

Press ON/BATTERY selector switch to the
BATTERY position. If the battery test
indicates weak batteries, replace them with
new ones. See “Replacing the Batteries”
on page 24.

Shorted or opened
cable

Check connections, in-line equipment,
interconnecting cables, and auxiliary in-line
equipment.

Wattmeter out of
calibration

Check calibration. See “Calibrating the
Wattmeter” on page 28.

Intermittent or
inconsistent

Faulty transmission
line, line connections,
antenna, or load
conditions

Inspect and correct meter operation or
load.

Dirty line section, DC
contact, and/or
element

Clean line section and element. See
“Cleaning” on page 21.

Sticky meter

Replace meter. See “Replacing the Meter”
on page 25.

High VSWR or
high
percentage

reflected
power

Bad load or poor
load, antenna, or
connectors

Replace connectors. See “Replacing the
Instrumentation Module” on page 26.

Shorted or open
transmission line

Replace transmission line.

Foreign material in
line section or in RF
connector bodies

Check for foreign material and clean as
required. See “Replacing the Meter” on
page 25.

PROBLEM

POSSIBLE

CAUSE

CORRECTION