Chapter 4 operating instructions, Normal operation, Operation under abnormal conditions – Bird Technologies 8920 Series User Manual
Page 19: Shutdown, Emergency shutdown
9
Chapter 4
Operating Instructions
Normal Operation
Bird 8920 series loads have no indicators or operating controls. They require no special operating procedures or surveil-
lance when their performance limits are not exceeded. Follow the instructions for the specific transmitter equipment.
Operation Under Abnormal Conditions
The load can be subjected to moderate overloads for short periods. If this is likely, make sure the interlock is prop-
erly connected to prevent damage to the load.
Shutdown
These loads are passive devices, so have no way of being turned off. Turn off RF power at the source.
Emergency Shutdown
Turn off RF power at the source.
If the interlock thermoswitch is properly connected, RF power will be automatically turned off when the coolant
temperature reaches an unsafe level.
WARNING
The vent plug must be used at all times when the unit is operating or cooling. Failure to do so could result in an
explosion or severe burns.
WARNING
Never attempt to connect or disconnect RF equipment from the transmission line while RF power is being
applied. Leaking RF energy is a potential health hazard.