Specifications – Bird Technologies 8890-320 Series User Manual
Page 32

20
Specifications
Frequency Range
8891D300, 8892D300,
8892D13-30, 8892D320
All other models
470 – 860 MHz
DC – 2.4 GHz
Power Rating
*
Peak Power for Pulse Width
†
1 µs
10 µs
100 µs
1000 µs
5000 µs
* Power rating with blower installed and operating: 5000 W
Power rating with blower installed and NOT operating: 1250 W
† Set the duty factor so that the average power rating of the load is not exceeded.
2500 W continuous duty
150 kW
115 kW
80 kW
54 kW
22 kW
Impedance
8896
All other models
51.5 ohms
50 ohms
VSWR
‡
8891D300, 8892D300,
8892D13-30, 8892D320
All other models
**
‡ VSWR measured using a female N connector.
** For models 8890-300, -315, and -320 VSWR Measured using a female N connector
1.065
DC – 1 GHz
1.1
1 – 2 GHz
1.25
2 – 2.4 GHz
1.3
Connectors
8890
8891, 8891D300
8892, 8892D300, 8892D320
8892D13-30
8895
8896
8897
8898
Female LC
3-1
/8” EIA flanged
1-5
/8” EIA flanged
Female 13-30
1-5
/8” EIA unflanged
3-1
/8” unflanged (flush center)
3-1
/8” unflanged (flush center)
3-1
/8” unflanged (recessed center)
AC Power
–315
–320
115 V ±10% @ 50/60 Hz ±3%
230 V ±10% @ 50/60 Hz ±3%
AC Line Power Rating
460 W max
IEC (5 x 20 mm) Type T
Fuse Rating
115 Vac
230 Vac
1 A
500 mA
Thermoswitch
Interlock
Fan Control
Normally closed. Opens at 236 °C (457 °F)
Normally open. Closes at 155 °C (311 °F)
Thermoswitch Rating
115 Vac
230 Vac
10 A
5 A
Ambient Temperature
–40 to +45 °C (–40 to +113 °F)
Altitude
††
†† Derate RF power by 2.5% for every 305m (1,000 ft.) above 1,520m (5,000 ft.).
1520 m (5000 ft.)
Humidity
95% noncondensing max
Cooling method
Oil dielectric and convection currents
Dimensions
Without blower
With blower
21.75" L x 7.5” W x 17.25" H (551 x 190 x 437 mm)
21.75" L x 7.5” W x 21
7
⁄
8
" H (551 x 190 x 556 mm)
Weight, Nominal
59 lb. (27 kg)
Finish