Maintenance

15

6. Replace the entire load resistor assembly. It cannot be further

disassembled.

7. Put the clamping band in place and tighten it.

8. Remove the shipping plugs. Install the vent plugs.

Storage and Shipment

Cover the load before storing to keep out dust and dirt. It is not
necessary to install the shipping plugs. Store in a dry, dust-free
environment where the ambient temperature will remain between

–40 and +45 °C (–40 to +113 °F).

To ship the load, take the following precautions:

"

Remove both vent plugs and replace them with the shipping
plugs. Wrap the vent plugs with padding and tape them to the
side of the load for protection.

NOTE: With the shipping plugs installed, it is not necessary to
empty out the coolant.

"

Wrap the connector in padding.

"

Pack and brace the load in a sturdy wooden crate for shipment.

Customer Service

Any maintenance or service procedure beyond the scope of those in
this chapter should be referred to a qualified service center.

If you need to return the unit for any reason, contact the Bird Service
Center for a return authorization. All instruments returned must be
shipped prepaid and to the attention of Bird Service Center.

Bird Service Center

30303 Aurora Road

Cleveland (Solon), OH 44139-2794

Phone: (440) 519-2298

Fax: (440) 519-2326

For the location of the Sales Office nearest you, give us a call or visit
our Web site at:

http://www.bird-electronic.com