Controller – Bendix Commercial Vehicle Systems EC-30 ABS/ATC CONTROLLER 2/08 User Manual
Page 26

26
SECTION G - TROUBLESHOOTING POWER TO THE EC-30
™
CONTROLLER
D u e t o c o r r o s i o n , d a m a g e o r 
poor termination, the wiring and/
or connectors may be limiting the 
electrical current fl ow to the EC-30
™
controller. This means that when the 
EC-30
™
controller needs more current,
the voltage level may be dropping. 
In order to measure the voltage 
under load, place a load, such as a 
type 1157 stop lamp bulb, between 
ignition power (pins B1, K2, K3) and 
ground (pins A1, A2, A3) at the 30-pin 
connector. While the lamp is in place, 
measure the voltage across the pins. It 
is important to check each power and 
ground pin combination. The operating 
range of the EC-30 is 9.0-16.0 VDC. 
Verify a measurement equal to battery 
voltage. (About 12.0 VDC) The loaded 
voltage should drop no more than 1.0 
VDC from the measured unloaded 
voltage.
ABS Warning lamp is on and green 
VLT LED is off or fl ashing.
Turn the ignition off and disconnect 
the 30-pin connector from the EC-30
™
controller.
Turn the ignition on and measure voltage 
between ignition power (pins B1, K2, 
K3) and ground (pins A1, A2, A3) at the 
30-pin connector. It is important to check 
each power and ground pin combination. 
The operating range of the EC-30
™
controller is 9.0 -16.0 VDC. Verify a 
measurement equal to battery voltage. 
(About 12.0 VDC) 
With a volt/ohm meter, check the 
power wiring, ground wiring and 
fuse. Look for corroded or damaged 
wires or connectors. When repair 
is made, reconnect the 30-pin 
connector to the EC-30
™
controller
and rerun the power up sequence.
Go to Section A.
With a volt/ohm meter, check the 
power and ground wiring. Look 
for corroded or damaged wires 
or connectors. If repair is made, 
reconnect the 30-pin connector to 
the EC-30
™
controller and rerun the
power up sequence.
Go to Section A.
Measure the loaded 
voltage across a type 
1157 stop lamp bulb.
1
2
3
K J H G F E D C B A
30-Pin Connector
YES
NO
A1,A2,A3
Ground
B1,K2,K3
Power
If proper loaded and unloaded voltage 
is measured at the 30-pin connector 
and no corrosion or damage is found 
on the EC-30
™
controller connector,
replace the EC-30
™