Reminder Messages

GFCI Protection
Your spa may be equipped with a GFCI Protection feature. If
your spa does have this feature enabled, the GFCI Trip Test
must occur to allow proper spa function.

Within 1 to 7 days after startup, the spa will trip the GFCI to
test it. (The number of days is factory programmed.) The GFCI
must be reset once it has been tripped. After passing the
GFCI Trip Test, subsequent GFCI trips will indicate a ground
fault or other unsafe condition requiring the power to the spa
to be shut off.

USER CAN SUPPRESS ALL REMINDERS IN USER PREFERENCES.

Message* Frequency**

Action Required

Check pH

Every 7 days

Test and adjust pH chemical levels per manufacturer’s instructions.

Check Sanitizer

Every 7 days

Test and adjust sanitizer chemical levels per manufacturer’s instructions.

Clean Filter

Every 30 days Remove, clean, and reinstall filter per manufacturer’s instructions.

Test GFCI

Every 30 days Test & reset GFCI per manufacturer’s instructions.

Drain Water

Every 90 days Drain and refill spa per manufacturer’s instructions.

Clean Cover

Every 180 days Clean and condition cover per manufacturer’s instructions.

Treat Wood

Every 180 days Clean and condition wood per manufacturer’s instructions.

Change Filter

Every 365 days Install new filter.

Change Cartridge As needed

Install new Mineral cartridge.

* All of these Periodic Messages can be disabled individually by the spa manufacturer.

** Any of these frequencies may be changed by the spa manufacturer.

Warning: The Owner should test and reset the GFCI on a
regular basis to verify its function.

Note: The GFCI section does not apply on EL systems used outside the United States and Canada.

GFCI Test Procedure

The installer can cause the GFCI Trip Test to occur sooner
by initiating it with the following button sequence.

Home > Set >

> Diagnostics >

> GFCI Test >

>

GFCI Trip >

.

The GFCI should trip within several seconds and the spa
should shut down. If it does not, shut down the power
and manually verify that a GFCI breaker is installed and
that the circuit and spa are wired correctly. Verify the
function of the GFCI with its own test button. Restore
power to the spa and repeat the GFCI Trip Test.

Once the GFCI is tripped by the test, reset the GFCI and
the Spa will operate normally from that point.

You can verify a successful test by pressing:
Home > Set >

> Diagnostics >

> GFCI Test, and

verifying that it says “Passed” on the top line of the GFCI
test screen.

GFCI PROTECTION AND TESTING