Rockwell Automation 20B Power Components Repl. Instructions - Frame 5 User Manual
Installation instructions
Installation Instructions
3
SCR, Brake IGBT, Power Module, Thermistor, Power Supply Board,
Power Interface Board, & Current Transducer Replacement - Frame 5
1
L1
L2
L3
O
I
=
A. Remove front covers.
B. Disconnect cables from cassette. Remove cassette.
C. Remove the Plastic Shield by taking out the screws.
D. Remove the screws securing the HIM Support Plate.
Disconnect cables. Remove HIM Support Plate and set
aside.
E. Locate component(s) to be replaced.
HIM Support Plate
Remove Screws
(6 Places)
Plastic Shield
Power Interface Board
See Steps
Current Transducers
See Steps
-
Thermistor
See Steps
Power Modules
See Steps
SCRs & Brake
IGBT
See Steps
-
on page
WIRE RANGE: 14-1/0 AWG (2.5-35 MM
2
)
TORQUE: 32 IN-LB (3.6 N-M)
STRIP LENGTH: 0.67 IN (17 MM)
USE 75 C CU WIRE ONLY
POWER TERMINAL RATINGS
WIRE RANGE: 6-1/0 AWG (16-35 MM
2
)
TORQUE: 44 IN-LB (5 N-M)
STRIP LENGTH: 0.83 IN (21 MM)
GROUND TERMINAL RATINGS (PE)
300 VDC EXT PWR SPLY TERM (PS+, PS-)
WIRE RANGE: 22-10 AWG (0.5-4 MM
2
)
TORQUE: 5.3 IN-LB (0.6 N-M)
STRIP LENGTH: 0.35 IN (9 MM)
17
21
INPUT AC
OUTPUT
Optional
Communications
Module
9
2
DC–
DC+
0V
0V