Specifications – Rockwell Automation 1440-RMA00-04RC XM-440 Master Relay Module User Manual
Page 10

10
Rockwell Automation Publication ENMON-IN440I-EN-P - February 2014
XM-440 Master Relay Module
Specifications
The following table lists the technical specifications for the XM-440 module.
Attribute XM-440
Temperature, operating
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
-20…65 °C (-4…149 °F)
Temperature, surrounding air, max
65 °C (149 °F)
Temperature, nonoperating
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
-40…85 °C (-40…185 °F)
Relative humidity
IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
5…95% noncondensing
Vibration
IEC 60068-2-6 (Test Fc, Operating)
2 g @ 10…500 Hz
Shock, operating
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
15 g
Shock, nonoperating
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
20 g
Emissions
CISPR 11 (IEC 61000-6-4)
Class A
ESD immunity
IEC 61000-4-2
4 kV contact discharges
8 kV air discharges
Radiated RF immunity
IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz
3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
EFT/B immunity
IEC 61000-4-4
±2 kV at 5 kHz on power ports
±1 kV at 5 kHz on relay and shielded signal ports
±1 kV at 5 kHz on XMbus port
Surge Transient immunity
IEC 61000-4-5
±1 kV line-earth(CM) on relay ports
±2 kV line-earth(CM) on shielded signal ports
±2 kV line-earth(CM) on XMbus port
Conducted RF immunity
IEC 61000-4-6
10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Enclosure type rating
None (open-style)
Voltages/ranges
Supply:
24V DC, 0.2A max, Class 2/SELV
Relay:
250V AC, 50/60 Hz, 3 A resisitive
Power dissipation
3.4 W max
External over-current protection
440-5AFUSEKIT for SELV/PELV power sources
Isolation voltage
250V (continuous), Basic Insulation Type, relay to relay and to all other circuits
Type tested at 1500V AC for 60 s