Description of pds2win messages, Sequence of events function blocks, Process historian function blocks – Rockwell Automation T7836 ICS Regent+Plus PDS to Winternet Conversion Package User Manual
Page 10
PDS to W
INTERPRET
Conversion Package
(T7836)
1 0
I n d u s t r i a l C o n t r o l S e r v i c e s
W
INTERPRET
function block the enable and reset contacts are
left blank, the timing interval is one program scan. These
values will cause the scaling function block to execute once
each application program scan, which is how they were
executed in previous PDS versions.
Sequence of Events Function Blocks
All information with the exception of descriptions is converted.
In W
INTERPRET
the description fields are automatically linked
to the tag name descriptions defined in the I/O and shared
variable editors.
Process Historian Function Blocks
All information with the exception of descriptions is converted.
In W
INTERPRET
the description fields are automatically linked
to the tag name descriptions defined in the I/O and shared
variable editors.
Description of PDS2WIN Messages
During the conversion process PDS2WIN displays a variety of
messages that report the progress of the file conversion.
These messages are listed and described below.
converting function block name
This is a progress message indicating the function block
currently being converted.
converting program name
This is a progress message indicating the program
currently being converted.
Could not convert function block name in program program
name.
The function block is an unsupported language.
function block name is not converted. (Language is
currently unsupported.)
The function block is a continuous control function
block and isn't available in W
INTERPRET
. Or the