9

Installation

Protect the drive from dirt, moisture, and accidental contact. Provide
sufficient room for access to the terminal block and calibration trimpots.

Mount the drive away from other heat sources. Operate the drive within
the specified ambient operating temperature range.

Prevent loose connections by avoiding excessive vibration of the drive.

Mount the drive with its board in either a horizontal or vertical plane. Six
0.188 inch (4.8 mm) wide slots in the chassis accept #8 pan head screws.
Fasten either the large base or the narrow flange of the chassis to the
subplate.

The chassis must be earth grounded for noise suppression. To ground the
chassis, connect earth ground to the GND terminal on terminal block 501
(TB501).

Mounting chassis drives

ATTENTION:

This drive contains ESD (Electric Static Discharge)

sensitive parts and assemblies. Static control precautions are required
when installing, testing, servicing, or repairing this assembly. Failure
to observe these precautions could result in damage to, or destruction
of, the equipment.

ƽ