Rockwell Automation GV3000/SE AC Drive Quick Reference Version 6.06 User Manual
Rockwell Automation Equipment
Alarm Codes
AIn
Analog Input Signal Loss
HIdc
High DC Bus Warning
I-Ac
V/Hz Identification Active
I-En
V/Hz Identification Enabled
LIL
Low Input Line
S-Ac
Vector Self-Tuning Active
S-En
Vector Self-Tuning Enabled
Fault Codes
AIn
Analog Input Signal Loss
bYC
DC Bus Charging Bypass Not Closed
CHS
Checksum Error
EC
Earth Current Failure (Ground Fault)
EEr
Non-volatile Memory Failure
EL
Encoder Loss
FL
Function Loss
HId
V/Hz Identification Aborted
HIL
High Input Line
HU
High DC Bus Fault
IPL
Input Phase Loss
LU
Low DC Bus Fault
nCL
Network Comm Loss
nId
V/Hz Identification Not Performed
OC
Overcurrent
OCA
Overcurrent at Acceleration
OCb
Overcurrent at DC Braking
OCd
Overcurrent at Deceleration
OF
Overfrequency
OH
Drive Overtemperature
OL
Motor Overload
OPL
Motor Output Phase Loss
OSP
Overspeed (Vector Only)
PUc
Missing Power Module ID Connector
PUn
Power Module Not Identified
PUo
Power Module Overload
SF
Vector Self-Tuning Aborted
Srl
Serial Comm Lost
UAr
PC Comm Spurious Interrupt
UbS
Asymmetrical Bus Charge
ATTENTION: This material is not intended
to provide operational instructions. Qualified
electrical personnel must read and
understand the applicable instruction
manuals in their entirety prior to installing,
adjusting, operating, and servicing this
equipment. Failure to observe this
precaution could result in severe bodily
injury or loss of life.
Printed in U.S.A. D-157-2 March 2001
Regulator Board Terminal Strip
1. RS-232
Transmit*
2. RS-232
Receive*
3. RS-232
Common*
4. Encoder +15 Volts
5. Encoder Phase A
6. Encoder Phase A Not
7. Encoder Phase B
8. Encoder Phase B Not
9. Encoder
Common
10. Analog Meter Output
11. Analog Meter Common
12. Isolated Reference Voltage
13. Vdc Analog Speed Reference
14. mA Analog Speed Reference
15. Isolated Reference Ground
16. Digital Input +24 Volts
17. Digital Input 8 (Rem/Loc)
18. Digital Input 7 (Ramp1/Ramp2)
19. Digital Input 6 (Fwd/Rev)
20. Function Loss
21. Run/Jog
22. Reset
23. Stop
24. Start
25. +24 Vdc Common
26. Snubber Resistor Braking Output*
27. +24 Vdc Common*
28. N.C. Relay Contact**
29. N.C. Relay Common**
30. N.O. Relay Contact**
31. N.O. Relay Common**
*Not available on Bookshelf drives.
**Located on remote terminal strip on Bookshelf drives.
Refer to the following software (S/W) and hardware (H/W)
manuals for detailed information about the GV3000/SE AC
drive.
GV3000/SE Drive
S/W I/M
H/W I/M
1 to 400 HP @ 460 VAC
D2-3359
D2-3360
75 to 200 HP @ 460 VAC
D2-3391
D2-3392
1 to 20 HP @ 230 VAC
D2-3387
D2-3388
30 to 100 HP @ 230 VAC
D2-3416
D2-3417
2 to 30 A Bookshelf
D2-3426
D2-3427
RMI Terminal Strip
41. Digital Input 1
42. Digital Input 2
43. Digital Input 3
44. Digital Input 4
45. Digital Input +24 Vdc
46. Digital Output External +24 Vdc
47. Digital Output 1
48. Digital Output 2
49. Digital Output 3
50. Digital Output 4
51. Digital Output Common
52. Relay 1 Common
53. Relay 1 N.O.
54. Relay 2 N.C.
55. Relay 2 Common
56. Relay 2 N.O.
57. Not Used
58. Relay 3 N.C.
59. Relay 3 Common
60. Relay 3 N.O.
61. Not Used
62. Analog Input 0 – 10 Vdc
63. Analog Input 0 – 20 mA
64. Analog Input Common
65. Analog Output 1: 0 to 10 Vdc
66. Analog Output 2: +/- 10 Vdc
67. Analog Output 3: 0 to 10 Vdc; 0 to 20 mA
68. Analog Output Common
69. Frequency Input: 0 to 200 kHz
Refer to the following manual for detailed information
about the Super Remote Meter Interface (RMI) board:
•
D2-3341
Super Remote Meter Interface (RMI)
Board for use with GV3000/SE and
VTAC 7 Drives
GV3000/SE AC Drive
Quick Reference
Version 6.06
D-157-2