Rockwell Automation 2364E Non-Regenerative DC Bus Supply Unit (NRU) User Manual
Page 27
Publication 2364E-5.01 April 2002
Your 180A DC NRU (Current Code A)
2-3
Important: The Powermonitor II standard configuation works with
grounded-wye secondary supplies only. For more
information on Powermonitor II configurations for other
supply types, consult Powermonitor II documentation
and the Power Quality and Automation group located in
Milwaukee, WI, USA.
D11
C11
DC HORIZONTAL BUS TO INVERTER UNITS
-BUS
HEAT
SINK
HEAT
SINK
D1
D3
D5
D2
D4
D6
HS1
HS2
EA2
+BUS
-BUS
LED2
LED1
PL1
(JMPR)
INTERLOCK
OPTIONAL
REMOTE
3
1
INVERTER UNITS
CONTROL BUS TO
N
L1
115 VAC
115 VAC NRU
CONTROL POWER
R12
R11
VM1
TB1-1
TB1-2
EA5-CR
S1
S2
CR1
CR2
PL2
MTR1
TB1-9
TB1-10
PE
F8
F7
F1
F2
F3
F6
F4
A
(FROM PREVIOUS PAGE)
CR1
CR2
TB1-3
TB1-4
TB1-5
TB1-6
F1
F2
R1
R2
Door-mounted ammeter option.
Powermonitor II option.
Line RC suppressor option.
Ground-fault detection option.
Air-flow sensing option.
(X1)
(X2)
PT1
115 VAC
+BUS
Control bus option.
Unit-not-faulted pilot light option.
Note: An NRU may have either a door-
mounted ammeter or a Powermonitor II. This
drawing shows both options for information.
F O O T N O T E S :
Powermonitor II communication module option.
DC bus voltmeter option.
CH11
CH11
(X3)
(X4)
(X1)
(X2)
- 20P PowerFlex DC Drive - Frame D Bimetal Thermostat (10 pages)
- 1336S_F_T_E_R F Frame Snubber Resistor Repl. (6 pages)
- 22-COMM PowerFlex 4-Class DSI (Drive Serial Interface) Network Communication Adapter (4 pages)
- 8-545 Plug In Solid State Relay (2 pages)
- 20-HIM-B1 PowerFlex 7-Class HIM Bezel (DPI) (4 pages)
- 100 Contactors with DC Coil (1 page)
- 100 Contactors with DC Coil (2 pages)
- 20P PowerFlex DC Drive - Frame D Switching Power Supply Circuit Board (6 pages)
- 140G-MTFx_MTHx_MTIx_MTKx Trip Unit Installation-140G-M (6 pages)
- 45BRD Analog Laser Sensor (4 pages)
- 20D Multi-Device Interface Option Board for PowerFlex 700S Drives (20 pages)
- 56RF RFID 18 mm Cylindrical Transceiver (2 pages)
- 42KC Miniature Rectangular: 5V DC Version (2 pages)
- 20P PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board (16 pages)
- 21P-MISC-A-TP-2 Transition Tube Kit #C19-6/7 For PowerFlex 755 w/OEM Liquid Cooling Fr 6/7 Drive (2 pages)
- 42BT Background Suppression Sensor (3 pages)
- 42CB High Speed 18mm Cylindrical (4 pages)
- 140EX-JE2_JE3 Molded Case Circuit Breaker (4 pages)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (1 page)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (3 pages)
- 20-HIM-A6 PowerFlex (Human Interface Module) (74 pages)
- 42CF General Purpose 12mm Cylindrical (4 pages)
- 20D PowerFlex 700S Phase II Drive Frames 1...6 (80 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (6 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (4 pages)
- 20B PowerFlex 700 Custom Firmware - Pump Off (12 pages)
- 20-WIM-N4S DPI Wireless Interface Module (92 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (7 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (2 pages)
- 60-2619, 42JS Swivel/Tilt Mounting Bracket (1 page)
- 22A PowerFlex 4/40/400 Flange Mount (4 pages)
- 45MLA Controller Installation Instructions (16 pages)
- 20P PowerFlex DC Drive - Cooling Fan for Frame A Drives Above 73A at 230V 460V AC (6 pages)
- 42JS Series 7000 to 42JS VisiSight Replacement Kit (2 pages)
- 22A PowerFlex 4-Class HIM Bezel (DSI) (4 pages)
- 42CS Stainless Steel Photoelectric Sensors (4 pages)
- 20L-LL PowerFlex 700L Liquid-to-Liquid Heat Exchanger (40 pages)
- 20P PowerFlex DC Drive - Frame B SCR Modules (20 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (161 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (22 pages)
- 22F PowerFlex 4M Input RFI Filters (2 pages)
- 45LFM Capacitive Label Sensor (4 pages)
- 140G-Rx Installation Instruction-140G-R (2 pages)
- 140G-Rx Installation Instruction-140G-R (29 pages)
- 22C PowerFlex 400 AC Drive Quick Start - FRN 1-4.xx (28 pages)