beautypg.com

Rockwell Automation 2090-U3CBB-DM12 CN1 Control Interface with Integral 24V-to-5V Power Installation Instructions User Manual

Installation instructions, About the control interface breakout boards

background image

Installation Instructions

Control Interface Breakout Boards
with 24V-to-5.2V Auxiliary Power
Converter

Catalog Numbers

2090-U3CBB-DM44, 2090-U3CBB-DM12

About the Control Interface Breakout Boards

These boards provide discrete wire termination for signals on the CN1 I/O connector of
Ultra3000 2098-DSD-005, 2098-DSD-010, and 2098-DSD-020 drives.

The 12-pin board (catalog number 2090-U3CBB-DM12) is intended for SERCOS drives but
may be used in non-SERCOS applications with minimal I/O requirements.

Each board includes an isolated 24V-to-5.2V DC auxiliary power converter, which simplifies
control power connections for Ultra3000 2098-DSD-005, 2098-DSD-010, and 2098-DSD-020
drives.

Refer to the Ultra3000 Digital Servo Drives Installation Manual, publication

2098-IN003

, for

additional information about these signals.

ATTENTION: These breakout boards contain electrostatic discharge (ESD)
sensitive parts that can be damaged if you do not follow ESD control procedures. If
you are unfamiliar with ESD control procedures, refer to Guarding Against
Electrostatic Damage, publicaton

8000-4.5.2

, or any other applicable ESD

protection handbook.