beautypg.com

Connecting ac power, Wiring guidelines (eu installations only) – Rockwell Automation 2706 Dataliner 20 Message Display User Manual

Page 11

background image

Dataliner DL20 Message Display

11

Connecting AC Power

The table below shows the electrical ratings for the Dataliner DL20 display.

Type of Display

Supply Voltage

Power Consumption

One and Two Line

100-240V ac, 50/60 Hz

30 VA maximum

Four Line

100-240V ac, 50/60 Hz

45 VA maximum

!

ATTENTION:

The Dataliner DL20 display is designed for safe use

when installed in a suitably rated NEMA Type 12, 13, 4X (indoor use
only), IP54 or IP65 enclosure.

!

ATTENTION

: Do not apply power to the display until all wiring

connections have been made. Failure to do so may result in electrical
shock.

Wiring Guidelines (EU Installations Only)

10 cm (4 in.) Maxi-

mum

L1

To

Dataliner

AC Input

To

AC Mains

Supply

L2N

L1

L2N

For installations within the European Union use the following guidelines to minimize
Radio Frequency Interference (RFI) and achieve maximum Electromagnetic
Compatibility (EMC).

Follow all local safety regulations regarding proper grounding.