Connect the upload/download cable, Prepare the panelview 1200 terminal – Rockwell Automation 2711-KTUY2KF PV 1200 Serial Firmware Upgrade Utility User Manual
Page 3
PanelView 1200 Series F and G
3
Connect the Upload/Download
Cable
The upload/download cable (Catalog No. 2711-NC1) links the RS-232 port
on the terminal with a serial port (usually COM1 or COM2) on a personal
computer. Make sure the cable connectors are fully inserted and secure. If
you require more information refer to the PanelView 1200 Operator
Terminal user manual or installation data sheet provided with the upload/
download cable.
Prepare the PanelView 1200
Terminal
Before downloading firmware, you must first prepare the PanelView 1200
terminal for the download:
1. Set the Mode Select keyswitch to Configure mode.
2. Choose Serial Port on the Configuration Mode menu. Make sure that
the PanelView 1200 terminal serial port is set as follows:
Baud Rate: 9600
Parity: None
Data Bits: 8
Stop Bits: 1
Handshake Type: None
Important: If you need more information about changing serial port values
of the operator terminal, refer to the user manual (Publication 2711-812)
3. After changing/verifying the serial port settings, select Save & Edit
button to save these settings and return to the Configuration Mode menu.
4. Select Upload/Download from the Configuration Mode Menu.
The Upload/Download screen is displayed.