beautypg.com

Troubleshoot with the indicators – Rockwell Automation 1738-SSIM23 ArmorPoint I/O SSI Absolute Encoder Module, Series A User Manual

Page 9

background image

Publication 1738-IN013A-EN-E - June 2004

ArmorPoint I/O Synchronous Serial Interface (SSI) Absolute Encoder Module, Series A 9

Message Size: 2 Bytes

Troubleshoot with

the Indicators

Byte

Bit

Description

Consume 0

7

6

5

4

3

2

1

0

Master ACK Byte

1

RES

RES

RES SCMP2 SCMP1 CC2 CC1 LACK

Consume 1

7

6

5

4

3

2

1

0

CONS1

RES

RES

RES

RES

RES

RES RES

RES

1

The master must provide the Master ACK Byte in order to receive the polled Produced bytes 0-9.

Indication

Probable Cause

Module Status

Off

No power applied to device

Green

Device operating normally

Flashing Green

Device needs commissioning due to missing, incomplete, or
incorrect configuration

Flashing Red

Recoverable fault

Red

Unrecoverable fault - may require device replacement

Flashing Red/Green

Device is in self-test

RUN

UP

DOWN

COMP

MOD

NET

1738-SSIM23/A

SSI Encoder

1

Module Status Indicators

43814

1738-SSIM23

Network Status Indicators

I/O Status Indicators