beautypg.com

European hazardous location approval – Rockwell Automation 1734-IV4/C Point I/O Source Input Module Installation Instructions User Manual

Page 19

background image

POINT I/O Source Input Module 19

Publication 1734-IN052D-EN-E - February 2005

European Hazardous Location Approval

European Zone 2 Certification (The following applies when the product
bears the EEx Marking)

This equipment is intended for use in potentially explosive atmospheres as defined
by European Union Directive 94/9/EC.
DEMKO certifies that this equipment has been found to comply with the Essential
Health and Safety Requirements relating to the design and construction of Category
3 equipment intended for use in potentially explosive atmospheres, given in Annex
II to this Directive. The examination and test results are recorded in confidential
report No. 03NK21595.
Compliance with the Essential Health and Safety Requirements has been assured by
compliance with EN 50021.

IMPORTANT

Observe the following additional Zone 2 certification
requirements.

• This equipment is not resistant to sunlight or other sources

of UV radiation.

• The secondary of a current transformer shall not be

open-circuited when applied in Class I, Zone 2 environments.

• Equipment of lesser Enclosure Type Rating must be installed

in an enclosure providing at least IP54 protection when

applied in Class I, Zone 2 environments.

• This equipment shall be used within its specified ratings

defined by Allen-Bradley.

• Provision shall be made to prevent the rated voltage from

being exceeded by transient disturbances of more than 40%

when applied in Class I, Zone 2 environments