Rockwell Automation 1746-QS QUICK START SYNCHRONIZED AXES User Manual
Synchronized axes control module, Quick start, Catalog number 1746-qs)
Publication 1746-10.3 – December 1997
Synchronized Axes Control Module
(Catalog Number 1746-QS)
Use this abbreviated procedure for getting the 1746-QS module into operation.
The following software and documentation are available for download from our website:
•
User Manual for the Synchronized Axes Control Module, publication 1746-6.19
•
Hydraulic Configurator Software to set up, tune, and troubleshoot axis movement
•
Ladder Logic File of example logic to sequence module operation to the machine
Chapter references in this procedure refer to the user manual, publication 1746-6.19.
1.
System Requirements for the Synchronized Axes Control System
Chapter 1
In addition to the 1746-QS module, you must have (or purchase) the following:
– PC with 4 MByte of available disk space
– Interface Module (terminal blk) (1492-AIFMQS)*
– Windows ’95
operating system
– Interface Module cable (1492-ACABLExxxQS)*
– SLC 5/03 processor (or later) with M0/M1 files
– Interface cable: PC to QS (1747-CP3)
– Comm. Interface (1784-KTX) if using SLC 5/04
– RSLogix500 Ladder Logic Software
* Required for CE Certification. Otherwise, recommended for wiring convenience.
2.
System Configuration and Wiring
Chapter 2
Important: Connect the following to earth ground: a) all cable shields (except for amplifier output cable)
at one end only b) LDT flange and machine frame c) IFM Terminal Block GND terminal 51 d) I/O chassis
Drive Output
Valve
Servo or
Proportional
Amplifier
24V Power
Supply
"15V Power
Supply for LDTs
earth ground
(+) (–)
(–) (C) (+)
Belden
8761
Belden
8761
Belden
8770
Piston-type Hydraulic Cylinder and
Linear Displacement Transducer (LDT)
0V (internal)
+
–
Pwr
Int
Ret
Axis Loop 1 of 4-axis system
IFM Terminal Block
Cat. No. 1492-AIFMQS
Cable 1492-
ACABLExxxQS
Belden
8105
Connect cable shields of servo
amplifier and LDT to SH termi-
nals on terminal block.
HYDRAULIC
SYNCHR AXES
1746-QS
module
1747-CP3
Cable
PC
Important: The module’s
analog outputs require an
external amplifier to drive
the valve.
Quick Start
Document Outline
- 1746-10.3, Synchronized Axes Control Module Quick Start
- System Requirements for the Synchronized Axes Control System
- System Configuration and Wiring
- Connect LDT to Interface Module Terminal Block
- Get Manual, Hydraulic Configurator Software, & Ladder Logic Files from the Internet
- Set Up Communication Between PC and QS Module
- With Hydraulic Configurator, Set Up and Tune Each Axis
- Create Ladder Logic to Run Your Application
- Back Cover