B-c jumper settings, P.272 [e-fld volts adj – Rockwell Automation 1397 Enhanced Field Supply Csrd User Manual
Page 11
![background image](/manuals/578877/11/background.png)
1397–5.12 June, 1997
1397 Enhanced Field Supply Card
11
0
1
2
3
4
5
6
7
8
9
000
0.4502
0.4502
0.4503
0.4505
0.4507
0.4510
0.4514
0.4518
0.4523
0.4529
010
0.4536
0.4543
0.4551
0.4559
0.4568
0.4578
0.4589
0.4600
0.4612
0.4624
020
0.4637
0.4651
0.4665
0.4681
0.4696
0.4712
0.4729
0.4747
0.4765
0.4784
030
0.4803
0.4823
0.4844
0.4865
0.4886
0.4909
0.4931
0.4955
0.4979
0.5003
040
0.5028
0.5054
0.5080
0.5106
0.5133
0.5161
0.5189
0.5217
0.5246
0.5276
050
0.5306
0.5336
0.5367
0.5398
0.5429
0.5461
0.5494
0.5527
0.5560
0.5593
060
0.5627
0.5661
0.5696
0.5731
0.5766
0.5801
0.5837
0.45873
0.5909
0.5946
070
0.5983
0.6020
0.6057
0.6094
0.6132
0.6170
0.6208
0.6246
0.6284
0.6323
080
0.6362
0.6400
0.6439
0.6478
0.6517
0.6556
0.6595
0.6635
0.6674
0.6713
090
0.6752
0.6792
0.6831
0.6870
0.6909
0.6940
0.6988
0.7027
0.7066
0.7104
100
0.7143
0.7182
0.7220
0.7259
0.7297
0.7335
0.7373
0.7410
0.7448
0.7485
110
0.7522
0.7559
0.7596
0.7632
0.7668
0.7704
0.7739
0.7774
0.7809
0.7844
120
0.7878
0.7912
0.7945
0.7978
0.8011
0.8043
0.8075
0.8107
0.8138
0.8169
130
0.8199
0.8229
0.8258
0.8287
0.8316
0.8344
0.8371
0.8398
0.8425
0.8451
140
0.8477
0.8502
0.8526
0.8550
0.8573
0.8596
0.8618
0.8640
0.8661
0.8682
150
0.8702
0.8721
0.8740
0.8758
0.8775
0.8792
0.8809
0.8824
0.8838
0.8854
160
0.8867
0.8881
0.8893
0.8905
0.8916
0.8926
0.8936
0.8945
0.8954
0.8962
170
0.8969
0.8975
0.8981
0.8986
0.8991
0.8995
0.8998
0.9000
0.9002
0.9003
180
0.9003
—
—
—
—
—
—
—
—
—
B-C Jumper Settings
Enhanced Field Supply Jumper Set to B-C
Drive
Minimum Output
Maximum Output
Input Volts
Motor Field Volts
Motor Field Volts
230V AC
0.45V DC
0.9V DC
LINE
CT
707973-5R
SP4
582
583
581
F1/37
F2/35
FC3
B
C
A
FC2
FC4
P4
P4
P4
X1
X2
H2
H1
Example
A 230V AC, 60Hz input is connected to the drive. The drive’s output is
connected to a 15HP DC motor with a nameplate field voltage of
150V DC.
The Line Multiplier =
150 = 0.6522
230
0.6522 is within the B-C jumper range of 0.45-0.9. In the B-C Jumper
Settings table, 0.6522 is closest to 0.6517. Therefore:
1. Set Enhanced Field Supply Jumper to B-C.
2. Set drive Regulator Board Jumper J21 to B-C.
3. Set parameter
P.272 [E-Fld Volts Adj]
to 84 —
080 + 4
.
P.272
→
↓