Shaft extension and method of drive, Shaft loads – axial and radial – Rockwell Automation 1325L DC Motors User Manual User Manual
Page 10
10
DC Motors
Shaft Extension and Method Of Drive
V-belts should be within the limits of NEMA Standard MG1-14.67.a.
Frames DC180ATZ, C180ATZ, DC210ATZ are supplied with the same size
shaft for either coupled or belted drives.
Table C Multipliers for Drives other than V-belt
1
The above multiplier is intended for use with conventional single-ply flat, belts. When other than single-ply flat belts
are used, the use of a larger multiplier is recommended.
2
It is often necessary to install belts with a snug fit. However, tension should be no more than necessary to avoid
belt slap or tooth jumping.
Shaft Loads – Axial and Radial
DC motors are suitable for limited shaft load as shown in Tables
and
.
Recommended maximum thrust loads depend on the mounting position,
either horizontal or vertical. For load recommendations in excess of those
shown, contact your local Sales Office.
Table D Axial Thrust Capacity
1
1
Thrust capacity for vertical mounting includes a constant whose value is plus or minus depending on the
direction of the thrust load. The constant is plus for thrust loads acting upward against the force of gravity and
minus for loads acting downward with gravity.
Drive
Multiplier
Flat Belt (See Note 1)
1.33
Timing Belt (See Note 2)
0.9
Chain Sprocket
0.7
Spur Gear
0.75
Helical Gear
0.85
!
ATTENTION: The use of these radial load capacities requires
the accurate calculation of the radial load for the application.
Radial loads for gears, sprockets, and flywheel are usually
accurately determined but the radial loads due to V-belt drives are
subject to miscalculations because they do not include all of the
pre-tension load (belt tightening). The calculations of the radial
load for a V-belt drive must include the pre-tension for
transmitting the horsepower, pre-tension for centrifugal force on
the belts, pre-tension for high start torques, rapid acceleration or
deceleration, pre-tension for drives with short arc-of-contact
between the V-belt and sheave, and low coefficient of friction
between belt and sheave caused by moisture, oil or dust. Failure
to observe these precautions could result in damage to or
destruction of the equipment.
Frame
Units
Horizontal Mounting
Vertical Mounting
2500 RPM 1750
1150
850
2500
1750
1150
850 RPM
DC180ATZ &
DC210ATZ
lbs.
176
207
251
286
190
±
45
217
±
45
265
±
45
295
±
45
kg
80
94
114
130
86
±
20
99
±
20
120
±
20
134
±
20
C180ATZ
lbs.
295
345
417
477
370
±
45
357
±
45
430
±
45
492
±
50
kg
134
156
189
216
139
±
20
162
±
20
195
±
20
223
±
20