beautypg.com

Shaft extension and method of drive, Shaft loads – axial and radial – Rockwell Automation 1325L DC Motors User Manual User Manual

Page 10

background image

10

DC Motors

Shaft Extension and Method Of Drive

V-belts should be within the limits of NEMA Standard MG1-14.67.a.
Frames DC180ATZ, C180ATZ, DC210ATZ are supplied with the same size
shaft for either coupled or belted drives.

Table C Multipliers for Drives other than V-belt

1

The above multiplier is intended for use with conventional single-ply flat, belts. When other than single-ply flat belts
are used, the use of a larger multiplier is recommended.

2

It is often necessary to install belts with a snug fit. However, tension should be no more than necessary to avoid
belt slap or tooth jumping.

Shaft Loads – Axial and Radial

DC motors are suitable for limited shaft load as shown in Tables

D

and

E

.

Recommended maximum thrust loads depend on the mounting position,
either horizontal or vertical. For load recommendations in excess of those
shown, contact your local Sales Office.

Table D Axial Thrust Capacity

1

1

Thrust capacity for vertical mounting includes a constant whose value is plus or minus depending on the
direction of the thrust load. The constant is plus for thrust loads acting upward against the force of gravity and
minus for loads acting downward with gravity.

Drive

Multiplier

Flat Belt (See Note 1)

1.33

Timing Belt (See Note 2)

0.9

Chain Sprocket

0.7

Spur Gear

0.75

Helical Gear

0.85

!

ATTENTION: The use of these radial load capacities requires
the accurate calculation of the radial load for the application.
Radial loads for gears, sprockets, and flywheel are usually
accurately determined but the radial loads due to V-belt drives are
subject to miscalculations because they do not include all of the
pre-tension load (belt tightening). The calculations of the radial
load for a V-belt drive must include the pre-tension for
transmitting the horsepower, pre-tension for centrifugal force on
the belts, pre-tension for high start torques, rapid acceleration or
deceleration, pre-tension for drives with short arc-of-contact
between the V-belt and sheave, and low coefficient of friction
between belt and sheave caused by moisture, oil or dust. Failure
to observe these precautions could result in damage to or
destruction of the equipment.

Frame

Units

Horizontal Mounting

Vertical Mounting

2500 RPM 1750

1150

850

2500

1750

1150

850 RPM

DC180ATZ &
DC210ATZ

lbs.

176

207

251

286

190

±

45

217

±

45

265

±

45

295

±

45

kg

80

94

114

130

86

±

20

99

±

20

120

±

20

134

±

20

C180ATZ

lbs.

295

345

417

477

370

±

45

357

±

45

430

±

45

492

±

50

kg

134

156

189

216

139

±

20

162

±

20

195

±

20

223

±

20