beautypg.com

Connector dimensions, Cable bend radius – Rockwell Automation 1326-xxxx Cables with Right Angle Connectors User Manual

Page 2

background image

Publication 1326A-IN024B-EN-P - May 2007

2 Right-angle Connection for Series B 1326 Cables

Connector Dimensions

This table lists dimensions for the 1326-xxx-RAL-xxx and 1326-xxx-RBL-xxx
connectors.

Cable Bend Radius

The table and diagram depict the minimum bend radius for cables. Bend
radius is the tightest (minimum) curvature allowed without potential damage
to the cable.

Cable

Height, Approx.

mm (in.)

Diameter,
Approx.

mm (in.)

Diameter at Bellows,
Approx.

mm (in.)

1326-CCUT-RAL-

xxx

, 1326-CCUT-RBL-

xxx

66.80 (2.63)

40.38 (1.59)

38.61 (1.52)

1326-CECUT-RAL-

xxx

, 1326-CECUT-RBL-

xxx

66.80 (2.63)

40.38 (1.59)

38.61 (1.52)

1326-CPB1T-RAL-

xxx

, 1326-CPB1T-RBL-

xxx

69.85 (2.75)

46.99 (1.85)

45.47 (1.79)

1326-CPC1T-RAL-

xxx

, 1326-CPC1T-RBL-

xxx

84.07 (3.31)

57.15 (2.25)

55.37 (2.18)

ht

Height

Diameter

Height

Height

Diameter

Diameter
at bellows

1326-xxx-RA-xxx
and 1326-xxx-RB-xxx

1326-xxx-RAL-xxx
and 1326-xxx-RBL-xxx

Dimensions for the

1326-

xxx

-RAL-

xxx

and

1326-

xxx

-RBL-

xxx

Connectors

Motor Power Cable
Catalog Number

1326-CCUT-xxx

1326-CECUT-xxx 1326-CPB1T-xxx 1326-CPC1T-xxx Bend Radius Diagram

BR, Approx

(1)

mm (in.)

50.8 (2.0)

120 (4.7)

104.1 (4.1)

160.2 (6.3)

(1)

Bend radius (BR) is the specified minimum bend radius for cable assemblies. For non-flex cables, BR is a one-time flex application. Flex cables have a much higher BR to
withstand flex applications. The BR for user-fabricated cables may vary.

BR

Bend Radius