Rockwell Automation 1329I ACDrive/Motor SerA Quick Ref User Manual
Page 2
PE
DC+
DC-
DBR
T/L3
S/L2
R/L1
DC Bus (Do Not Wire)
DBR (Do Not Wire)
AC Inputs
AC Input Power Connections
1
2
34
5678
9
1
0
11
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
10 Volt Reference
0 – 10V DC Speed Reference Input
4 – 20 mA Speed Reference Input
Common
0 – 10 Volt Output
Common
Speed Preset 2
Speed Preset 1
Speed Preset 0
Forward/Reverse
24 Volt DC
RPM/Percent Load Display
Reset
Start
Stop
24 Volt DC Common
N.O. Relay
Relay Common
24 Volt DC
➊
Function Loss
➊
-
+
RPM
% Load
OFF ON
Enabled
Terminal Block
Faulted
Enabled
Constant
Ramp-to-Rest
Disabled
From Terminal Block
Run On Power Up
Speed Reference
➊
Relay Control Output
Auto Restart
Torque Curve
Stop
Reverse
Minimum Speed
Not Used
Not Used
Disabled
Operator Controls
Running
Disabled
Variable
Coast-to-Rest
Enabled
3 Hz
Setup DIP Switch (SW3)
➊
Switch 2 applies to local operator control units only.
1
2
34
5678
9
1
0
11
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
10 Volt Reference
➊
0 – 10V DC Speed Reference Input
4 – 20 mA Speed Reference Input
Common
0 – 10 Volt Output
Common
Speed Preset 2
Speed Preset 1
Speed Preset 0
Forward/Reverse
24 Volt DC
RPM/Percent Load Display
Reset
Start
Stop
24 Volt DC Common
N.O. Relay
Relay Common
24 Volt DC
➋
Function Loss
➋
-
+
+10V DC
5K
Ω
RPM
Fwd
Rev
% Load
13
16
17
Maintained 2-Wire Start.
Momentary 3-Wire Start.
0 = 1 Second Accel/5 Sec Decel
1 = 5 Seconds (Default)
2 = 10 Seconds
3 = 15 Seconds
4 = 20 Seconds
5 = 30 Seconds
6 = 60 Seconds
7 = 90 Seconds
0 = 1500 RPM (50 Hz)
1 = 1800 RPM (60 Hz) Default
2 = 2100 RPM (70 Hz)
3 = 2400 RPM (80 Hz)
4 = 2700 RPM (90 Hz)
5 = 3000 RPM (100 Hz)
6 = 3300 RPM (110 Hz)
7 = 3600 RPM (120 Hz)
Max Speed Switch (SW2)
Accel/Decel Switch (SW1)
ATTENTION: All adjustments to these components
should be made with the power removed. Failure to
observe this precaution could result in severe bodily
injury or loss of life.
ATTENTION: After disconnecting input power, wait
five minutes and check with voltmeter to assure that
DC bus capacitors are discharged (DC+, DC-).
The voltmeter should read zero volts.
Control Signal Terminal Block
ATTENTION: The cover screws must be securely
tightened in order to properly ground the cover.
Verify that all four cover screws are tight before
applying power to the unit. Failure to observe this
precaution may result in severe bodily injury or loss
of life.
Standard Unit
Local Operator Control Unit
Connect to external device.
➋
The jumber between terminals 7 and 11 must be removed when wiring the Function Loss input.
See Section 7.1 of the User Manual for more information.
➊
An external 0 to 10 volt or 4 to 20 mA speed reference source can be connected.
See Section 7.5.3 of the User Manual for more information.
= N.O. Momentary Contact
= N.C. Momentary Contact
= Maintained Contact - Closed
= Maintained Contact - Open
Ground
= Default Setting (OFF Position)
Connect to external device.