Rockwell Automation 1394 Upgrading Your Axis Module User Manual
Page 8
Upgrading your Axis Module
8
Publication 1394–6.2 – March 1997
Re-mounting the Axis Module
To re-mount the axis module:
1. Install the top mounting fastener on the system panel for the axis
module. The head of the fastener should be at least 0.25 in. from
the panel.
2.
If you are mounting
an AM50/75:
Do this:
With the heat sink
through the back of
the enclosure
1. Remove the paper backing from
the gasket that came with the kit.
2. Position the gasket so that the
small hole side is on top.
3. Slide the gasket over the heat sink
and attach it to the back of the axis
module.
4. Go to step 3.
With the heat sink
inside the enclosure
Go to step 3.
3. Hang the AM50/75 axis module on the mounting fastener.
4. Engage the alignment tab.
5. Slide the slide-and-lock mechanism on the AM50/75 axis module
to the left until it locks into place.
6. Install the lower fastener for the AM50/75 axis module.
7. If not already attached, attach the terminator to the last axis
module slide-and-lock mechanism until it locks in place.
8. Tighten all mounting fasteners.
9. Reconnect TB1, TB2, motor, and ground wires.
10.Apply power to the system.
11. Verify that the system is operating properly.
Note: Because system and axis parameters reside in the
system module software, you do not need to perform
any tuning or setup at this time.
gasket
Engaged alignment tab