Rockwell Automation 1326AB_AB-MOD-G Air-Over Blower Option User Manual
Page 2
1326AB Air-Over Blower Option
Instructions
2
The following specifications apply to either kit.
Specifications
Input Voltage
220/240V AC, 50/60 Hz., single-phase
Line Amperes
0.15 / 0.14
Locked Rotor Amperes
0.23 / 0.23
Fan Output
240 CFM
Air Inlet Clearance
6 inches (152.4 mm)
Weight
4 lbs. (1.81 kg)
Important: The 1326AB-MOD-G3 and G4 option kits must not be used in
environments requiring IP65 protection.
Installation
The following steps provide the information needed to properly install the
Air-Over Blower option. Refer to Figure 1 for further information.
ATTENTION: To avoid a shock hazard, assure that all power
to the controller has been removed before performing the
following.
!
1326AB-MOD-G3
1. Assure that all power to the controller/motor has been removed.
2. Orient the blower housing as shown in Figure 1.
3. Secure the housing to the motor using the supplied standoffs and
screws.
4. Connect 240V AC power to the leads of the blower.
5. Check operation.
1326AB-MOD-G4
1. Assure that all power to the controller/motor has been removed.
2. Grasp the blower housing and spread it slightly, while sliding it over
the shaft end of the motor.
3. Continue sliding the housing on until it meets the front flange of the
motor. When completely installed, the housing will surround the motor.
4. Align one of the five metal standoffs between the two holes on either
side of the housing. Repeat for the remaining standoffs.
5. Connect 240V AC power to the leads of the blower.
6. Check operation.