MSR41 Safety Module User Manual

Original instructions

Figure 6: MSR41 base module, Micro 400 Light Curtain, automatic start, output monitoring

Figure 7: MSR41 Base module and MSR45E expander module, Micro 400 Light Curtain,
automatic start, output monitoring

Status outputs

The MSR41 base module has two status outputs (“Info1” and “Info2”).
A description of these outputs is given below.

The following table shows the logic of the two status outputs. The state
of the status outputs will also be displayed through LED, visible on the
front side of the main module.

Table 1

LED display elements

MSR41 base module

Table 2 gives information about the LED on the front side of a MSR41
base module with the basic configuration:

Table 2: LED description

Response time

General

• The response time of a MSR41 base module depends on the

connected GuradShield Micro400 Light Curtain length and
resolution.

• The response time for the MSR41 base module [t(totLCOSSD)]

with respect to the Micro400 light curtain is the sum of the base
module response time t(C) + the response time of the light curtain
t(LC):
t(totLCOSSD)= t(C) + t(LC)

• The response time for the MSR45E expander module (relay safety

output) [t(totLCEXT)] with respect to the Micro400 light
curtain is the sum of the base module response time
t(totLCOSSD) + the response time of the expander module
t(em):
t(totLCEXT)= t(totLCOSSD) + t(em)
=t(C) + t(LC) + t(em)

The total response time of a system is the sum of each response time:

Table 3: Calculation for the total response time of the Micro400 safety light curtain

Terminal

(LED)

Output "high"

(+24V)

Output "low"

(0V)

Info1 (LED)

Start ok (green)

No start possible (red)

Info2 (LED)

System okay (green)

Error (Lock out) (red)

These outputs may not perform any
safety relevant functions. They serve only
to communicate the status to a machine
controller.

LED

Signal / Color / Status

Signal / Color / Status

OSSD2

+24 V / green /

Light curtain not activated

(free)

0 V / red / Safe400

Light curtain activated

(interrupted)

OSSD1

+24 V / green /

Light curtain not activated

(free)

0 V / red / Safe400

Light curtain activated

(interrupted)

Info2 (LED)

See page 3

See page 3

Info1 (LED)

See page 3

See page 3

IN2

+24 V / green /

start release okay

0 V / red /

no start release signal

IN1

not used / green

not used / green

0 V

-

-

+24 V

+24 V / green /

power connected

0 V / off /

no power connected

Response time MSR41

Max. OSSD response time for Micro400
light curtain

t(totLCOSSD) = 9.10ms(t(c)) + t(LC)
from the Micro400 label

Response time first,
2nd and 3rd expander
module

Max. relay extension module response
time for Micro400 light curtain

t(totLCEXT) = 9.10ms(t(c)) +
6.00ms(t(em)) + t(LC) from the
Micro400 label